ILMOR ONE-TOUCH Owner's Manual page 23

Hide thumbs Also See for ONE-TOUCH:
Table of Contents

Advertisement

4. Connect the harness for the hydraulic valve unit backup switch stored
in the boat to the hydraulic valve unit and the three pins connector
with the removed cap.
EPV driver
5. Turn on the engine only in the side where the hydraulic valve unit
backup switch is connected, and start the engine.
6. Press the arrow switch of the hydraulic valve backup switch to adjust
the cylinder and bring the stern drive in a straight condition (center).
Contraction direction of the hydraulic cylinder
Expansion direction of the hydraulic cylinder
7. After adjusting the cylinder, stop the engine, and turn off the power.
And remove the backup switch. After that, reinstall the cap.
8. And then carry out same procedure for other side drive also.
9. Disconnect the harness of the backup switch and connect the harness
(EPV driver) to the hydraulic valve unit as original condition and then
attach the cap for both side.
NOTE: If you connect the backup switch in case of emergency, be sure to
remove it after the adjustment. Do not reconnect the backup switch to the
original harness (EPV driver) until the repair is complete.
© 6/2016 Ilmor Marine Engines, Version 1.0
FAILURES AND CORRECTIVE ACTIONS
Hydraulic valve unit
Backup switch
Figure 4-3
Identification mark
Figure 4-4
041914-02EN00
041915-00E00
4-6