Audio Network Interface
General Description
The Shure ANI22 Audio Network Interface provides 2 channels of Dante-to-analog and 2
channels of analog-to-Dante conversion. A single interface provides a simple way to
connect analog equipment to the audio network, such as wireless microphones, audio
processors, video codecs, and loudspeaker systems. Available in XLR and block connector
versions, each box uses a single network cable to carry audio and power through Power
over Ethernet (PoE). A browser-based web application controls audio and network settings
from any computer connected to the same network.
Safety Information
IMPORTANT SAFETY INSTRUCTIONS
1. READ these instructions.
2. KEEP these instructions.
3. HEED all warnings.
4. FOLLOW all instructions.
5. DO NOT use this apparatus near water.
6. CLEAN ONLY with dry cloth.
7. DO NOT block any ventilation openings. Allow sufficient distances for adequate
ventilation and install in accordance with the manufacturer's instructions.
8. DO NOT install near any heat sources such as open flames, radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat. Do not place any
open flame sources on the product.
9. DO NOT defeat the safety purpose of the polarized or grounding type plug. A
polarized plug has two blades with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The wider blade or the third prong are
provided for your safety. If the provided plug does not fit into your outlet, consult an
electrician for replacement of the obsolete outlet.
10. PROTECT the power cord from being walked on or pinched, particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11. ONLY USE attachments/accessories specified by the manufacturer.
12. USE only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or
sold with the apparatus. When a cart is used, use caution when moving the
cart/apparatus combination to avoid injury from tip-over.
9/12/17, 9(22 AM
Page 1 of 35

Advertisement

loading

Summary of Contents for Shure ANI22-BLOCK

  • Page 1 General Description Safety Information Getting Started The Shure ANI22 Audio Network Interface provides 2 channels of Dante-to-analog and 2 Hardware and Installation channels of analog-to-Dante conversion. A single interface provides a simple way to connect analog equipment to the audio network, such as wireless microphones, audio Signal Flow and Connections processors, video codecs, and loudspeaker systems.
  • Page 2: Getting Started

    Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM 13. UNPLUG this apparatus during lightning storms or when unused for long periods of time. 14. REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is...
  • Page 3 2. Open the Shure Device Discovery application 3. Double-click the device to open the web application. Tip: If setting up multiple Shure devices, use the Identify button in the application to flash the lights on the device. Step 3: Connect Devices in Dante Controller Software 1.
  • Page 4 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM 1. Find the MXA310 in the list of Dante transmitters, and select the plus sign (+) to show all channels. 2. Find the ANI22 in the list of Dante receivers, and select the plus sign (+) to show all channels.
  • Page 5 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM Get More Information Now that the basic setup is complete, you should have access to the web application and be able to pass audio between devices. More comprehensive information is available...
  • Page 6 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM XLR Model: Signal/Clip Each indicator corresponds to a single channel. Analog and digital Indicators gain adjustments are made through the web application. If an input channel LED turns red, attenuate the level from the source device to prevent clipping at the input stage.
  • Page 7 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM -6 dBFS or more Audio and Logic Note: Logic connections are only featured on the block connector version. Connections Block Connector Pin Assignments: Input Audio + Audio - Audio ground...
  • Page 8 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM 3 Negative Chassis Ground Provides an optional connection for microphone shield wire to Screw chassis ground. LED Indicators Power: Power over Ethernet (PoE) present Note: Use a PoE injector if your network switch does not supply PoE.
  • Page 9 The reset button is located inside a small hole in the rear panel. Use a paperclip or other small tool to press the button. There are two hardware reset functions: Network reset (press Resets all Shure control and audio network IP settings to factory button for 4-8 defaults seconds)
  • Page 10 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM Align the holes as shown for securing a single device in the single-unit mounting tray Align the holes as shown for securing up to three devices in the 19" rack tray.
  • Page 11 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM Under-table Mounting 1. Align the ears with the mounting holes pointed upward. 2. Install the two screws that hold the ear to the tray as shown. Installing Underneath a Table http://pubs.shure.com/guide/ANI22/en-US...
  • Page 12 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM 1. Hold the tray in the desired location under a table 2. Use a pencil to mark the location of the mounting holes on the table. 3. Drill 4 holes for the screws. The diameter of the holes in the tray are 7.1 mm.
  • Page 13 Loudspeakers, amplifiers, or recording devices connect to the Devices analog line output Dante-enabled Dante microphones, such as the Shure Microflex Advance ceiling Equipment and table arrays connect to the network switch and can be routed using Dante Controller software. Control CPU A computer connected to the network accesses the web application to control the channel levels and processing.
  • Page 14: Using A Password

    Audio is encrypted with the Advanced Encryption Standard ( AES -256), as specified by the US Government National Institute of Standards and Technology (NIST) publication FIPS-197. Shure devices that support encryption require a passphrase to make a connection. Encryption is not supported with third-party devices.
  • Page 15 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM Settings menu and select the General tab. In this screen, passwords can be created or changed. Once a password has been set, a Read-Only option appears on the log-in screen. In Read- Only mode, device parameters can be viewed, but not edited.
  • Page 16 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM Output levels are controlled by the Digital Gain (dB) fader. Always adjust the input gain before the output gain. In most cases, setting the analog gain correctly results in an appropriate output level.
  • Page 17 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM Adjust filter settings by manipulating the icons in the frequency response graph, or by entering numeric values. Disable a filter using the check-box next to the filter. Filter Type Only the first and last band have selectable filter types.
  • Page 18 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM Copy and Paste Use to quickly apply the same PEQ setting across multiple channels. 1. Select the channel from the pull-down menu in the PEQ screen. 2. Select Copy 3. In the pull-down menu, select the channel to apply the PEQ setting and select Paste.
  • Page 19 If using unicast flows, each of these devices can connect with up to two Dante receiver devices. The Shure ANI4OUT connects with up to two Dante transmitter devices. Pushing Device Names to the Dante Network To send a device name to appear in Dante Controller, go to Settings>General and enter a http://pubs.shure.com/guide/ANI22/en-US...
  • Page 20: Event Log

    The Export feature creates a CSV (comma separated values) document to save and sort the log data. Refer to the log file for details when troubleshooting or consulting with Shure Systems Support. To view the event log: http://pubs.shure.com/guide/ANI22/en-US...
  • Page 21 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM 1. Open the Help menu 2. Select View Event Log Severity Level Information An action or event has been successfully completed Warning An action cannot be complete, but overall functionality is stable Error A problem has occurred that could inhibit functionality.
  • Page 22 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM Most parameters will send a REPORT command when they change. Thus, it is not necessary to constantly query parameters. The ANI22 will send a REPORT command when any of these parameters change.
  • Page 23 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM { yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy } is 31 characters of the user name. The ANI22 always responds with a 31 character > name. Get Device ID Command String: The Device ID command does not contain <...
  • Page 24 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM < REP PRESET2 {yyyyyyyyyyyyyyyyyyyyyyyyy} > < REP PRESET3 {yyyyyyyyyyyyyyyyyyyyyyyyy} > Get Audio Gain Command String: Where xx is ASCII channel number: 01 < GET xx AUDIO_GAIN_HI_RES > through 04. ANI22 Response: Where yyyy takes on the ASCII values of <...
  • Page 25 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM Command String: Where xx is ASCII channel number: 00 < SET xx AUDIO_GAIN yy > through 02. ANI22 Response: Where yy takes on the ASCII values of 00 < REP xx AUDIO_GAIN yy >...
  • Page 26 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM < REP xx AUDIO_MUTE OFF > Get Device Audio Mute Command String: < GET DEVICE_AUDIO_MUTE > ANI22 Response: The ANI22 will respond with one of these < REP DEVICE_AUDIO_MUTE ON >...
  • Page 27 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM AUX_LVL > < REP xx AUDIO_OUT_LVL_SWITCH MIC_LVL > Flash Lights on ANI22 Command String: Send one of these commands to the ANI22. < SET FLASH ON > The flash automatically turns off after 30 seconds.
  • Page 28 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM < SET LED_BRIGHTNESS n > 0 = LED disabled 1 = LED dim 2 = LED default ANI22 Response: < REP LED_BRIGHTNESS n > Get Audio Clip Indicator Command String: Where xx is ASCII channel number: 00 <...
  • Page 29 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM ANI22 Response: The ANI22 will respond with one of these < REP LIMITER_ENGAGED ON > strings. < REP LIMITER_ENGAGED OFF > Get Encryption Status Command String: < GET xx ENCRYPTION_CH >...
  • Page 30 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM < GET xx PEQ yy > yy is the PEQ filter 01-04 within the block. 00 can be used for all blocks or all filters. ANI22 Response: < REP xx PEQ yy ON >...
  • Page 31 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM ANI22 Response: The ANI22 will respond with one of these < REP HW_GATING_LOGIC ON > strings. < REP HW_GATING_LOGIC OFF > Get Mic Logic LED In Command String: < GET CHAN_LED_IN_STATE >...
  • Page 32: Information To The User

    Fax: +49-7262-92 49 11 4 Email: info@shure.de This product meets the Essential Requirements of all relevant European directives and is eligible for CE marking. The CE Declaration of Conformity can be obtained from Shure Incorporated or any of its http://pubs.shure.com/guide/ANI22/en-US Page 32 of 35...
  • Page 33: Specifications

    Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM European representatives. For contact information please visit www.shure.com Specifications Analog Connections Inputs Active Balanced ANI22-XLR (2) XLR connector ANI22-BLOCK (2) 6-pin block connector Outputs Impedance Balanced ANI22-XLR (2) XLR connector...
  • Page 34 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM typical 9.8 W (33.7 BTU/hr) Audio Frequency Response ±1 dB 20 to 20,000 Hz Dante Digital Audio Sampling Rate 48 kHz Bit Depth Latency Does not include Dante latency Analog to Dante 0.35 ms...
  • Page 35 Shure Publications | User Guides | ANI22 9/12/17, 9(22 AM Output Impedance 150 Ω Input Clipping Level Analog Gain Setting= +0 dB +20 dBV Analog Gain Setting= +27 dB -7 dBV Analog Gain Setting= +51 dB -31 dBV Analog Output Level...