5. T
D
ECHNICAL
ATA
5.4 S
TANDARDS CONFORMITY
1K(S)/2K(S)/3K(S)
Conducted Emission: EN50091-2
Radiated Emission: EN50091-2
Harmonic Current: EN61000-3-2
Voltage Fluctuations and Flicker: EN61000-3-3
EMS:
EN61000-4-2(ESD)
EN61000-4-3(RS)
EN61000-4-4(EFT)
EN61000-4-5( Lighting Surge)
EN61000-2-2(Immunity to low frequency signals)
6K
Conducted Emission:
EN50091-2 Rated output current exceeding 25A limits
Radiated Emission:
EN50091-2 Rated output current exceeding 25A limits
EMS:
EN61000-4-2(ESD)
EN61000-4-3(RS)
EN61000-4-4(EFT)
EN61000-4-5(Lighting Surge)
EN61000-2-2(Immunity to low frequency signals)
5.5 C
OMMUNICATION PORT
The UPS is equipped with a standard RS232 port to communicate with a host computer.
The RS232 communication port transmits both utility power and UPS status to the host
computer, providing the host computer with proprietary command sequence to monitor
the utility power and the UPS status and to control the UPS through WinPower software.
The data format of RS232 :
Baud Rate
: 2400 bps
Data Length
: 8 bits
Ending Bit
: 1 bit
Parity Bit
: none
Class B
Class B
Level 4
Level 3
Level 4
Level 4
Level 4
Level 3
Level 4
Level 4
10