Event Logging <Logging - Polycom Version 1.4.x 17 Administrator's Manual

Sip 1.4.0 soundpoint/soundstation ip sip
Table of Contents

Advertisement

Administrator Guide - SoundPoint
Attribute
ind.gi.x.y.class
ind.gi.x.y.physX
ind.gi.x.y.physY
ind.gi.x.y.physW
ind.gi.x.y.physH
4.6.1.16 Event Logging <logging/>
Logging parameter changes can impair system operation. Do not change any logging parameters
Warning!
without prior consultation with Polycom.
The event logging system supports the following classes of events:
Level
0
1
2
3
®
®
IP / SoundStation
IP
Permitted
Values
Interpretation
positive integer
Assigns the class (defined above) for this indicator.
IP 300: 0-19
For GraphicIcon type indicators, this is the x-axis loca-
tion of the upper left corner of the indictor measured in
IP 500: 0-159
pixels from left to right.
IP 600: 0-319
IP 4000: 0-247
IP 300: 0-3
For GraphicIcon type indicators, this is the y-axis loca-
tion of the upper left corner of the indicator measured in
IP 500: 0-79
pixels from top to bottom.
IP 600: 0-159
IP 4000: 0-67
IP 300: n/a
For GraphicIcon type indicators, this is the width of the
indicator measured in pixels.
IP 500: 1-160
IP 600: 1-320
IP 4000: 1-248
IP 300: n/a
For GraphicIcon type indicators, this is the height of the
indicator measured in pixels.
IP 500: 1-80
IP 600: 1-160
IP 4000: 1-68
Interpretation
Debug only
High detail event class
Moderate detail event class
Low detail event class
Copyright © 2004 Polycom, Inc