Panasonic KX-TDA100 Installation Manual page 132

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

2.8 Connection of DECT Portable Stations
b.
Overlap the CS coverage areas of at least 2 CSs at any location in the installation site.
Channel no. 0
Channel no. 2
c.
Make sure that the radio signal strength level is greater than "3" at any location in the
service area demanded by the user.
Notes
If a channel is set, the results of measurement for the 24 slots on the channel are
saved each time. If the same channel is set, the new results override the previous
ones. Therefore, a measurement of 10 channels × 24 slots in total can be made.
If correct results cannot be obtained (e.g., there are many error counters), change the
allocation of the CS and repeat the site survey to select the best location.
Referring the Stored Scan Data
Press 1, 9, and POWER
for more than 5 seconds.
To go to other slots
Previous or Next
Clearing the Stored Scan Data
When "CLEAR SCAN DATA" is displayed after turning on the PS, it is required to clear the scan
data.
Press 1, 9, and POWER
for more than 5 seconds.
132
Installation Manual
Log No.
To go to specific channel
Channel No.
/
0 to 9
GHI
0 to 9
Channel no. 1
Channel no. 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda200

Table of Contents