AccessZone ® - GC500 Series – GC501-GC504 User Manual
14.2 Detection range is to short
Follow and repeat these steps to increment the detection range:
Increase (+5) the <Detection range> value
If <Detection range> =99 is not enough - increase (+1) <TX power level> and set <Detection
range>=50
Check detection distance – follow adjusting procedure depending on result
Final adjustment can be done by changing (±1) the <Detection range> value.
14.3 Detection range is too long
Follow and repeat these steps to shorten the detection range:
Decrease (-5) the <Detection range>
If(<Detection range>=0) then decrease (-1) the <TX power level> value and set <Detection
range>=99
Check detection distance – follow adjusting procedure depending on result
The final adjustment can be done by changing (±1) the <Detection range> value.
All information is subject to change without notice. All other products and brand names are registered trademarks of their respective companies
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web
www.mvc-data.com
E-mail
info@mvc-data.com
2010-07-06 US 1.17