9 Request Exit – REX Push Button
Signals involved: Input 2 and Output 2
A REX push button can be connected to the system on input 2 (IN2). The REX push button must be
installed on the secured side and will allow easy exit by activating output 2 (OC2) without using a
mobile phone.
A mobile phone is required to arm/disarm the alarm system connected to output 1 (OC1). The REX
push button cannot do this alone. However, the REX push button is required with the alarm
arming and disarming feature.

10 Alarm Arming and Disarming

Signals involved: Input 2 and Output 1
The system can arm/disarm an alarm system. Output 1 (OC1) is a latched output and the signal can
be inverted. Refer to section 8.4 Change System Configuration Command 1
The REX push button on input 2 (IN2) is also used with this feature.

10.1 Disarming the Alarm

The system will disarm the alarm by activating output 1 (OC1) when a valid user with disarming
permission (refer to section 8.4 Change System Configuration Command 1) has been detected.
The alarm is kept disarmed until it is armed again.
Note!
Pressing the REX push button will only activate the door/gate – It cannot disarm the alarm.

10.2 Arming the Alarm

The system will arm the alarm again when a valid user with arming permission (refer to section 8.4
Change System Configuration Command 1) has been detected and the user afterward presses the
REX push button.
If the user can enable the alarm - one (long) beep acknowledge that the alarm will be
enabled
If the user cannot enable the alarm - two short beeps is given as warning
The alarm is kept armed until a valid user with disarming permission disarms it again.
All information is subject to change without notice. All other products and brand names are registered trademarks of their respective companies
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web
www.mvc-data.com
E-mail
info@mvc-data.com
2010-07-06 US 1.17
22/34
Phone +45 25 12 84 02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AccessZone GC501 and is the answer not in the manual?

This manual is also suitable for:

Accesszone gc504Accesszone gc502Accesszone gc503

Table of Contents