11 Virtual Keypad
The system has a wireless virtual keypad functionality which can operate in two different modes:
"Virtual Keypad only Mode" and "Virtual Keypad Mixed Mode"
This feature will allow access to all users that know the 4 digit access PIN code or to any with a
Bluetooth device.
11.1 Virtual Keypad only Mode
The system can be configured to run as a purely virtual keypad. I.e. no users have to be added. The
system administrator adds a user with the special BD address "FFFFFFFFFFFF" (not a valid BD
address) and a 4 digit access PIN code on storage position 03 (Refer to section 8.2 Add new User
Command).
The system will in this mode grant access to all users who enter the correct 4 digit access PIN code.
The request for PIN code is disabled when "0000" is entered as PIN code and thereby give access
to all with a Bluetooth enabled device – I.e. a simple gate or door opener.
The system administrator can at any time change the PIN code.
Caution!
If this special user is placed on storage position 01 or 02 all users will have the ability to add and
delete users (privileged user) - if they know the correct access PIN code and the Master PIN code.
This is not recommended.
11.2 Virtual Keypad Mixed Mode
The system can be configured to be a mixed mode virtual keypad with up to 4/9/19 or 49 unique
users and 2 privileged (number depends on purchased system version) and a virtual keypad user
with the special BD address "FFFFFFFFFFFF" (not a valid BD address) and a 4 digit access PIN code.
The system will in this mode grant access to all unique users with their unique 4 digit access PIN
code/no PIN code and all other users which enter the correct 4 digit virtual keypad access PIN
code.
This feature allows the virtual keypad PIN code to be changed frequently without affecting the
other unique users.
Caution!
The system will start to search for a match from position 01 going up. The virtual keypad user
must be placed after the last used storage position or store it on the last storage position
7/12/22 or 52, if you want to be able to add more users in the future.
All information is subject to change without notice. All other products and brand names are registered trademarks of their respective companies