Installation Guide
Elise3
4.6.5
Message Distribution
In the administration pages, there are distribution lists that are used to distribute incoming
information. The internal distribution is automatically set, but external distribution of
incoming data has to be configured separately.
Distribution of "Status Logs" and "Activity Logs" are configured separately. Advanced
settings for activity logs are described in the Function Description, Activity Logging in Unite,
TD 92341GB.
The addressing is described in the examples below:
Addressing another Unite compliant module on the LAN
The addressing includes the IP address that the data should be distributed to and also which
service on that address that should take care of it. How a product is addressed is described
in the documentation for each product.
• Addressing of another Unite compliant module
xxx.xxx.xxx.xxx/Service
First the IP address of the module is defined. After the "/", the application service that
should take care of the data is specified.
Below is an example that describes how to distribute data from an Elise3 software
application to an Alarm Management Server.
• Addressing of an Alarm Management Server
xxx.xxx.xxx.xxx/EventHandler
First the Alarm Management Server IP address is defined. After the "/", the application
service EventHandler is specified.
Addressing a module on the System 900 A-bus
When a specific module on the A-bus is addressed, the data will be transferred directly to
that module. It is however not necessary to address a specific module on the A-bus as the
Central Unit in the System 900 can distribute the data to a module. Note that this requires
configuration of the Central Unit.
• No module addressing
127.0.0.1/S900
The data is sent to the System 900 interface in the Elise3 module, which sends the data on
the A-bus without the module address defined. The Central Unit in the system has to be
configured to distribute the data to a module. It is also possible to address the System 900
interface on another module by entering its IP address instead of 127.0.0.1 (localhost).
• Module addressing
127.0.0.1/S900?03
The data is sent to the System 900 interface (127.0.0.1/S900) in the Elise3 module and is
then sent to the module with address 03 in the system. It is also possible to address the
System 900 interface on another module by entering its IP address instead of 127.0.0.1
(localhost).
22 November 2013 / Ver. G
4. Installation and Configuration
TD 92679EN
26