26

SAVE/UNDO of SETUP

Simply pressing these buttons saves the current panel setting to internal
memory or recalls the saved setting.
SETUP
Saves the current panel setting in internal memory. The internal memory
SAVE
stores the condition immediately before the last pressing of the button.
SETUP
Recalls the saved setup from the internal memory. Pressing this button
UNDO
again undoes the recalling and returns to the previous setup.
How to use SAVE/UNDO of SETUP
[Example] When two settings of measurement are switched alternately, one
at a sweep rate of 2 ms and the other at a sweet rate of 200 µs.
1. After measurement is performed at a sweep rate of 2 ms/div, press the
SAVE button.
2. Set a sweep rate of 200 µs/div and carry out measurement.
3. Pressing the UNDO button recalls the panel setting at a sweep rate of 2
ms/div.
4. Pressing the UNDO button again recalls the 200 µs/div panel setting.
Pressing the UNDO button toggles the sweep rate between 2 ms/div and
200 µs/div.
Saves/recalls the
displayed
CH1/CH2/CH3/CH4
waveforms simultaneously.
Save/recall of
reference waveform
Internal memory
Saves/recalls part of
readout and menu.
(For save content,
see Document 4.)
Save/recall of panel setting