Operating The Horizontal Axis; Time/Div, Delay, Zero Delay - Iwatsu DS-8814 Operation Manual

Table of Contents

Advertisement

16

Operating the horizontal axis

TIME/DIV
Sets the sweep rate per scale (approximately 9 mm). The setting range is
5 ns to 50 s/div in 1-2-5 sequence. When pressing the TIME/DIV knob
if FFT is not selected in Math, either 1-2-5 sequence or 1-10-100
sequence are set.
The waveform is expanded or reduced based on the screen center. (See
the figure below.) The operation varies depending on the delay setting.
When trigger delay is zero
Trigger point does not change
DELAY
Sets the position of the trigger point in the horizontal direction.
The Delay time is a time interval from the trigger point to the screen
center as the zero point. When pressing the knob, the COARSE setting
(COARSE) is then selected.
Note that the setting range of the delay time varies depending on the
sweep rate and memory length setting. (See Section 2.)
Observe waveform 1 ms after
trigger is generated.
Trigger delay=1 ms
Input signal
Trigger generation
Wave display screen
ZERO DELAY
Sets the trigger delay time to zero.
The trigger point comes to the screen center when zero.
Trigger point
Screen center
according to sweep time.
POST TRIGGER
Waveform data acquired
When trigger delay is non-zero
Trigger point
Screen center
Trigger point changes
according to sweep time.
PRE TRIGGER
Observe phenomenon before trigger is generated.
Screen center
Trigger generated
at right end of screen (minus 5 div)

Advertisement

Table of Contents
loading

Table of Contents