With separate housing

E E X X
Zone 1
Zone 1
Fig. 1:
Rod length L1 max. 4 m
Rope length L1 max. 9.7 m (the maximum total length is 10 m.)
Note!
• The maximum connection length between the probe and the separate housing is 6 m (L4).
When ordering a device with a separate housing, the desired length must be specified.
• Maximum total length: L1 + L4 = 10 m
• If the connecting cable is to be shortened or passed through a wall, it must be separated
from the process connection. See "Documentation" ... "Operating Instructions" see Page 75
3.6.1
Extension heights: separate housing
Housing side: wall mounting
B
~61 mm
Note!
The bending radius of the connecting cable must be at least r  100 mm!
£ £
L4
L4
6 m
6 m
Housing side: pipe mounting
~75 mm
B
Liquicap M FTI51, FTI52
E E X X
Zone 0
Zone 0
L00-FMI5xxxx-14-00-06-xx-003
Sensor side
³
r
100 mm
D
³
r
100 mm
L00-FMI5xxxx-06-05-xx-xx-049