Period Measurement - Siemens SIMATIC S7-300 FM 350-1 Manual

Counter
Table of Contents

Advertisement

Operating Modes, parameters and commands
7.4 Measuring modes
7.4.5

Period measurement

Period measurement
In period measurement mode, the FM 350-1 indicates the dynamic measuring time as a
period. If the period is less than the update time, then an average is calculated for the period.
The value of the calculated period is displayed in units 1 μs or 1/16 μs. You can read the
measured period at the feedback interface (Bytes 0 to 3).
Figure 7-34
Update Time
The FM 350-1 updates the measured values cyclically. You specify the update time with the
"Update time" parameter. You can change the update time during operation.
Table 7- 38
Calculating the Update Time
Boundary conditions
Non-isochronous mode
Isochronous mode
The decimal places obtained after division by T
1
It is prohibited to exceed these limits. If these limits are exceeded, the FM 350-1 generates a parameterization error and
does not switch to isochronous mode.
146
Period Measurement with Gate Function
Update time
Any T
n × 10 ms
DP
T
< 10 ms
n × T
DP
T
≥ 10 ms
n × T
DP
are omitted.
DP
n
min
1
(10 ms/T
[ms] ) +1
DP
DP
1
DP
Value range of n
n
max
12000
12000
1)
120000 ms/T
FM 350-1 Counter module
Manual, 05/2011, A5E03648639-01
[ms]
1)
DP