Checkback Interface For The Measuring Modes - Siemens SIMATIC S7-300 FM 350-1 Manual

Counter
Table of Contents

Advertisement

5.7.4

Checkback interface for the measuring modes

Checkback interface for the measuring modes
Table 5- 18
Checkback interface for the measuring modes (inputs)
Offset to the start
Parameter
address
Bytes 0 to 3
LATCH_LOAD
Bytes 4 to 7
ACT_CNTV
Bytes 8 to 9
DA_ERR_W
Byte 10
OT_ERR_B
Byte 11
PARA
FM_NEUST
FM_NEUSTQ
DATA_ERR
OT_ERR
DIAG
Byte 12
Byte 13
STS_GATE
STS_UFLW
STS_OFLW
STS_COMP1
STS_DIR
STS_RUN
FM 350-1 Counter module
Manual, 05/2011, A5E03648639-01
Assignment
Measured value
Counter value
Data error
Operator error
Bit 7: Parameter assignment done
Bit 6: Restart request
Bit 5: Restart acknowledgement done
Bit 4: Data error
Bit 3: Operator error
Bit 2: Diagnostics event
Bit 1: –
Bit 0: –
Bit 7: Reserve = 0
Bit 6: Reserve = 0
Bit 5: Reserve = 0
Bit 4: Reserve = 0
Bit 3: Reserve = 0
Bit 2: Reserve = 0
Bit 1: Reserve = 0
Bit 0: Reserve = 0
Bit 7: –
Bit 6: Gate status
Bit 5: –
Bit 4: Underflow
Bit 3: Overflow
Bit 2: End of measurement
Bit 1: Direction bit
Bit 0: Counter active
Programming the FM 350-1
5.7 Programming FM 350-1 without FCs
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents