Stopping the count using the gate stop function
You can also stop the count by setting the gate stop function, regardless of the status or
signals set at the SW gate. This is done by setting input parameter GATE_STP at
FC_CNT_CTL1.
When you reset this parameter, you can only retrigger the gate by setting a positive edge at
digital input DI-Start (HW gate), or you once again set input parameter SW_GATE.
Gate control in isochronous mode
SW gate control: To control the SW gate, you set and reset the SW_GATE control bit in the
user program. After the control bit has changed, the count starts and ends at time T
next PROFIBUS DP cycle:
Figure 7-15
FM 350-1 Counter module
Manual, 05/2011, A5E03648639-01
Starting and stopping the count using the SW gate (SW_GATE)
Operating Modes, parameters and commands
7.3 Count modes
in the
o
107