Icom IC-FR5100 Series Handbook page 16

Vhf and uhf fm repeaters
Table of Contents

Advertisement

INSTALLATION
• Install the UR-FR5100 or UR-FR6100(channel
extension module)
1. Attach the supplied angles to both sides of the
channel extension module, and tighten the 2
supplied screws (M4× 8) on each side.
2. Install the channel extension module using the
supplied screws (Tapping screws: M3× 8, Set screws:
M3×6) as shown below.
Channel extension
module
Channel module
(original)
• Connect the control cable
1.Connect the supplied control cable to J502 on the
front board as shown below.
2. Cut the rubber caps of the control cables, then
insert the rubber caps to the front panel's chassis as
shown below.
UR-FR5100/UR-FR6100 Installation
ASSEMBLE THE UNIT
1. Replace the rubber seal and shielding plate of the
front panel, then tighten the 6 screws.
• Make sure the rubber seal is properly seated in the
groove of the chassis.
• Be sure to match the correct positions of the holes of
the shielding plate and projections of the front panel's
chassis.
Set screws
Tapping
screws
2. Connect the control cables to the channel
modules.
Channel module
(original)
3. Return the front panel, top cover and screws to
their original positions.
Rubber seal
Projections
Channel extension module
Longer cable
(upper side)
Shorter cable
(lower side)
Holes
16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic-fr6100 series

Table of Contents