Ur-Fr5100/Ur-Fr6100 Installation - Icom IC-FR5100 Series Handbook

Vhf and uhf fm repeaters
Table of Contents

Advertisement

UR-FR5100/UR-FR6100 CHANNEL
EXTENSION MODULES
SUPPLIED ACCESSORIES
1. DC power cable
2.Control cable
3. Angles
4. Screws (M4× 8 mm)
5.Set screws (M3×6 mm)
6.Tapping screws (M3×8 mm)
1 mm = 1/32 inch
OPENING CASE
1. Remove 7 screws from top and 2 screws each from
both sides of the repeater, then slide off the top cover
to the direction of the arrow as illustrated below.
2.Remove 3 screws from bottom and 2 screws each
from both sides of the repeater.
3-1-2

UR-FR5100/UR-FR6100 Installation

:1
:1
:2
:4
:4
:2
3. Disconnect the control cable from the channel
module (original), then remove the front panel.
Channel module(original)
Front panel
4. Remove 6 screws from the front panel, then
remove the shielding plate and rubber seal.
Shielding plate
Rubber seal