3.7.7 Motor overtemperature input

The motor overtemperature input is a dedicated input which may be directly connected to the
motor's thermal switch. When the motor overheats and triggers the overtemperature input, the
MotiFlex e100 is normally disabled. See section 5.3.5 for details.

3.7.8 Bottom panel wiring

It is important that signal cables are properly shielded. Optional bracket OPT-CM-002 / -003
allows easy screening and attachment of other signal cables. See section A.1.6.
Baldor cables include an
individually shielded pair
for the motor's thermal
switch output.
Connect the shield to
earth using a conductive
P-clip or optional bracket
OPT-CM-002.
Use spare slots in
bracket OPT-CM-002 to
secure other cables,
such as drive enable
shown here.
Figure 20 - Bottom panel wiring using OPT-CM-002 / -003
MN1943
www.baldormotion.com
The feedback connector on
Baldor cables provides the
required shield connection.
When using a cable that does
not provide a shield at the
connector, bond the shield to
earth using a conductive
P-clip or optional bracket
OPT-CM-002.
When using the analog input,
use shielded twisted pair with
the shield connected to earth
using a conductive P-clip or
optional bracket OPT-CM-002.