Input / Output - Baldor MotiFlex e100 Installation Manual

Table of Contents

Advertisement

8.6 Input / output

8.6.1 Analog input - AIN0 (X3)
Type
Common mode voltage range
Input impedance
Input ADC resolution
Equivalent resolution (±10 V input)
Sampling interval
8.6.2 Digital inputs - drive enable and DIN0 general purpose (X3)
Type
Input voltage
Input current (maximum, per input)
Sampling interval
Minimum pulse width
8.6.3 Digital inputs DIN1, DIN2 - high speed general purpose (X3)
Type
Input voltage
Input current (maximum, per input)
Maximum input frequency
Minimum pulse width
MN1943
Unit
VDC
kΩ
bits
mV
μs
Unit
VDC
Nominal
Minimum
Maximum
Active
Inactive
mA
ms
μs
Unit
VDC
Nominal
Minimum
Maximum
Active
Inactive
mA
MHz
ns
www.baldormotion.com
All models
Differential
±10
120
12 (includes sign bit)
±4.9
250
All models
Opto-isolated inputs
24
12
30
> 12
< 2
50
1
5
All models
Opto-isolated inputs
24
12
30
> 12
< 2
20
1
250
Specifications 8-31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents