8.3.8 Motor output rating adjustment - 10.5 A model

The continuous current rating of the MotiFlex e100 is affected by the chosen overload type and
switching frequency, as shown in Table 24. These settings can be selected in the Mint
WorkBench Drive Setup Wizard - see the Mint help file for details.
300%, 3 s
overload
4 kHz
8 kHz
16 kHz
The continuous current ratings shown in Table 24 must be derated if the drive is operating in an
ambient temperature between 45 °C (113 °F) and the absolute maximum operating temperature
of 55 °C (131 °F):
When sharing the DC bus, it becomes critical to consider the overall power being
derived from the drive's internal power supply. See section 8.2.3.
CAUTION
8-20 Specifications
Servo motor
200%, 3 s
overload
8 A
12 A
7.33 A
10.5 A
5 A
7.5 A
Table 24 - Continuous current ratings for 10.5 A model
100
95
90
85
80
75
70
65
60
55
50
44
45
46
47
48 49 50 51 52 53 54 55 56
Ambient temperature (ºC)
Figure 88 - Temperature derating for 10.5 A model
Induction motor
150%, 60 s
110%, 60 s
overload
overload
16 A
18.5 A
13 A
15 A
8.5 A
9.5 A
www.baldormotion.com
Low
Stationary:
speed
speed
DC output
DC output
output
(any phase)
(< 2 Hz)
9.8 A
13.9 A (DC)
8 A
11.4 A (DC)
5.2 A
7.4 A (DC)
4 kHz
8 kHz
16 kHz
MN1943