8.3 Motor output

8.3.1 Motor output power (X1) - 1.5 A ~ 16 A models
Nominal phase current
Nominal output power
@ 415 V
Output voltage range (line-line)
@ VDC-bus = 600 V
Output frequency
Output dV/dt
at motor (using 20 m cable), phase-phase
at motor (using 20 m cable), phase-ground
Nominal switching frequencies
Minimum motor inductance
(per winding)
Efficiency
8.3.2 Motor output power (X1) - 21A ~ 33.5 A models
Nominal phase current
Nominal output power
@ 415 V, 3Φ input
Output voltage range (line-line)
@ VDC-bus = 600 V
Output frequency
Output dV/dt
at motor (using 20 m cable), phase-phase
at motor (using 20 m cable), phase-ground
Nominal switching frequencies
Minimum motor inductance
(per winding)
Efficiency
* 16 kHz not available on 33.5 A model.
MN1943
at drive, phase-phase
at drive, phase-ground
at drive, phase-phase
at drive, phase-ground
Unit
1.5 A
3 A
A
1.5
3
RMS
kVA
1.08
2.16
V
RMS
Hz
kV/μs
kHz
4.0, 8.0, 16.0
mH
%
Unit
21 A
A
21
RMS
kVA
15.10
V
RMS
Hz
kV/μs
kHz
4.0, 8.0, 16.0 *
mH
%
www.baldormotion.com
6 A
10.5 A
16 A
6
10.5
16
4.31
7.55
11.50
0 - 430
0 - 2000
2
1.1
1.9
1.8
1
>95
26 A
33.5 A
26
33.5
18.69
24.08
0 - 430
0 - 2000
2
1.1
1.9
1.8
1
>95