Ricoh U-C1 B051 Service Manual page 236

Table of Contents

Advertisement

26 July 2002
Mode No.
7
(Class 1, 2, and 3)
907
14
Tray 2 Roller
15
Tray 3 Roller
16
Tray 4 Roller
17
By-pass Feed
18
Paper Transfer Unit
19
Toner: M
20
Toner: C
21
Toner: Y
22
Toner: Bk
23
ADF
908
Process Control Counter
Process Control
1
Counter
909
Process Control Reset
1
Process Control Reset
913
Oil Counter
1
Oil Counter
914
Oil Clean Counter Reset
1
Oil Clean Counter
Reset
915
Process Error Log
1
Log 1
2
Log 2
3
Log 3
920
Machine Counter
1
Machine Counter
921
Machine Counter Clear
1
Machine Counter
Clear
922
Toner End Counter
1
K Toner
2
C Toner
3
M Toner
4
Y Toner
Function / [ Setting ]
[0 ~ 255 / 0 / 1 /step]
Displays the process control counter.
[0 ~ 9999999 / 0 / 1 sheet/step]
Resets the process control counter.
Displays the oil supply unit counter.
[0 ~ 65535 / 0 / 1 sheet/step]
Resets the oil cleaner counter.
Displays the latest three process control error logs.
The following are the error codes:
Development unit initial settings errors:
• 110: Incorrect image detected by cyan ID sensor
• 116: Incorrect image detected by magenta ID
sensor
• 118: No black image
Development bias settings errors:
• 113: Incorrect image detected by cyan ID sensor
• 114: Incorrect image detected by magenta ID
sensor
• 115: Incorrect image detected by yellow ID sensor
• 123: Incorrect image detected by black ID sensor
ID sensor errors:
• 103: ID sensor error
• 104: ID sensor unable to detect image
• 105: OPC belt not detected
[0 ~ 0xFFFFFFF / 0 / 1 /step]
Clears the machine counter.
Displays the toner end counter, which indicates the
possible print count after a toner near end.
5-61