26 July 2002
Mode No.
2
(Class 1, 2, and 3)
321
7
Normal/2nd/Trailing
edge
8
Thick/1st/Trailing edge
Thick/2nd/Trailing
9
edge
10
OHP/Trailing edge
322
Paper Transfer Charge
1
Leading edge
2
Trailing Edge
323
Paper Transfer Cleaning
1
Cleaning Negative
2
Cleaning Positive
3
Cleaning Negative
Lubrication
331
Print Start Cleaning
1
Print Start Cleaning
400*
Cleaning Bias LL1
1
1 Color
2
2 Colors-4 Colors
3
Half Speed/1 Color
4
Half Speed/2 Colors-4
Colors
5
ID pattern
6
No Image Area
7
Jam Recovery
401*
Cleaning Bias LL2
1
1 Color
2
2 Colors-4 Colors
3
Half Speed/1 Color
4
Half Speed/2 Colors-4
Colors
5
ID pattern
6
No Image Area
7
Jam Recovery
Function / [ Setting ]
Adjusts the paper transfer current at the paper edges.
[10.0 ~ 20.0 / 10.0 / 0.1 times/step] DFU
The specified values indicate how many times larger the
current at the edge is.
Adjusts the width at the paper edges where the current
specified with SP2–321 is applied.
[0 ~ 30 / 30 / 1 mm/step] DFU
The values indicate the distance from the paper edges.
Adjusts the transfer belt cleaning current. The current is
applied before and after printing jobs and during jam
recovery.
[0 ~ 255 / 150 / 0.1 µA/step] DFU
[0 ~ 255 / 150 / 0.1 µA/step] DFU
[0 ~ 255 / 50 / 0.1 µA/step] DFU
Enables/disables cleaning before printing jobs.
[0 ~ 1 / 0 / 1 /step] DFU
• 0: Disables
• 1: Enables
Adjusts the transfer belt cleaning voltage when absolute
3
humidity AH (g/m
) is in the following range:
0 < AH ≤ 3.5 (this is the 'LL1' humidity range) DFU
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
Adjusts the transfer belt cleaning voltage when absolute
3
humidity AH (g/m
) is in the following range:
3.5 < AH ≤ 8.0 (this is the 'LL2' humidity range) DFU
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
5-15
SERVICE PROGRAM MODE