Teledyne HDO8000A Getting Started Manual

Teledyne HDO8000A Getting Started Manual

High definition oscilloscopes

Advertisement

Quick Links

HDO8000A
High Definition Oscilloscopes
Getting Started Guide

Advertisement

Table of Contents
loading

Summary of Contents for Teledyne HDO8000A

  • Page 1 HDO8000A High Definition Oscilloscopes Getting Started Guide...
  • Page 3 However, clients are encouraged to duplicate and distribute Teledyne LeCroy documentation for internal educational purposes. HDO and Teledyne LeCroy are trademarks of Teledyne LeCroy, Inc. Windows is a registered trademark of Microsoft Corporation. Other product or brand names are trademarks or requested trademarks of their respective holders.
  • Page 4: Table Of Contents

    Welcome Thank you for buying a Teledyne LeCroy product. We’re certain you’ll be pleased with the detailed features unique to our instruments. This Getting Started Guide is designed to cover important safety and installation information for your oscilloscope, along with some basic operating procedures so you’re quickly working with waveforms.
  • Page 5 INTRODUCTION HDO8000A High Definition Oscilloscopes...
  • Page 6: Introduction

    24 channels provides the ability to quickly identify and isolate problems in an embedded system. on the HDO8000A with HD4096 technology are cleaner and crisper. Signal details often lost in the noise are clearly visible and easy to distinguish,...
  • Page 7: Specifications

    Specifications Materials List Detailed specifications are maintained in the Datasheet on the product Check that you have all the parts listed here. Contact Teledyne page at teledynelecroy.com. LeCroy immediately if any part is missing. • 1 oscilloscope Key Specifications •...
  • Page 8: General Safety Information

    INTRODUCTION General Safety Information Precautions • Use proper power cord. Use only the power cord shipped with this This section contains instructions that must be observed to keep the instrument and certified for the country of use. instrument operating in a correct and safe condition. You are required to follow generally accepted safety procedures in addition to the precautions •...
  • Page 9 HDO8000A will meet all specifications. Power and Grounding Warm up the HDO8000A for at least 20 minutes prior to use. During the The instrument operates from a single-phase, 100 to 240 Vrms (± 10%) warm-up period, the oscilloscope will automatically initiate calibrations to AC power source at 50/60 Hz (±...
  • Page 10: Support

    You can also select Support > OneTouch Help for a demonstration of MAUI with OneTouch. Teledyne LeCroy publishes a free Technical Library on its website at teledynelecroy.com/support/techlib. Manuals, tutorials, application notes, white papers, and videos are available to help you get the most out of your Teledyne LeCroy products.
  • Page 11 SET UP HDO8000A High Definition Oscilloscopes...
  • Page 12: Set Up

    SET UP The Front of Your Oscilloscope Touch Screen Display Front Panel Shortcut Buttons Built-in Stylus Holder Power Button Channel Inputs EXT Input Mixed Signal Interface Ground and Calibration Output Terminals USB Ports Tilting Feet...
  • Page 13 Ground and calibration output terminals are used to compensate passive probes. HDO8000A oscilloscopes are compatible with the included passive probes and all Teledyne LeCroy ProBus active probes that are rated for the oscilloscope’s bandwidth. Probe specifications and documentation are available at teledynelecroy.com/probes.
  • Page 14 SET UP The Back of Your Oscilloscope Built-in Carrying Handle B C D Ref In/Out connector to input/output an external Reference Clock Aux Out connector to send device trigger enabled, trigger out, or pass/ fail output to another device USBTMC Port for remote control Ethernet Ports (2) for LAN connection Host USB 3.0 Ports (4) Display Port for external monitor...
  • Page 15: Connecting To External Devices/Systems

    Printer Note: The oscilloscope touch screen uses Fujitsu drivers. Because of HDO8000A supports USB printers that are compatible with the Windows potential conflicts, external monitors with Fujitsu drivers cannot be used OS installed on the oscilloscope. Connect the printer to any host USB port, as touch screens, only as displays.
  • Page 16: The Side Of Your Oscilloscope

    SET UP The Side of Your Oscilloscope The side of the HDO8000A houses a removable hard drive. To remove the drive: Loosen the two knobs that secure the cover and remove it. You may use a screwdriver to loosen the knobs.
  • Page 17: Powering On/Off

    Powering On/Off Language Selection Connect the line cord rated for your country to the AC power inlet on the To change the language that appears on the display, go to Utilities > back of the instrument, then plug it into a grounded AC power outlet. Preference Setup >...
  • Page 18: Software Activation

    Software Activation Firmware Updates The oscilloscope operating software (firmware and standard applications) Free firmware updates are available periodically from the Teledyne LeCroy is active upon delivery. website at teledynelecroy.com/support/softwaredownload. Registered users will receive email notification when a new update is released. To...
  • Page 19: User Interface

    USER INTERFACE HDO8000A High Definition Oscilloscopes...
  • Page 20: Touch Screen Display

    USER INTERFACE Touch Screen Display The entire display is active. Use your finger to touch, drag-and-drop, swipe, pinch, and flick. Many controls that display information also work as “buttons” to access other functions. If you have a mouse installed, you can click anywhere you can touch to activate a control; in fact, you can alternate between clicking and touching, whichever is convenient for you.
  • Page 21 A toolbar along the bottom of the main Channel, Math, Memory and A drop-down menu bar lets you access set up dialogs and other Digital dialogs applies common actions so that you don’t have to leave functions. All functionality can be accessed through either the menu the underlying dialog.
  • Page 22: Changing The Display

    USER INTERFACE Changing the Display Q-Scape Multi-Tab Display The grid is 8 Vertical divisions representing 4096 Vertical levels and 10 Horizontal time divisions. The value represented by each division depends In addition, the grid area can be divided into multiple tabs. Each tab can on the scale settings of the traces that appear on it.
  • Page 23 Extended Display Line and Intensity If you have a second monitor connected, select Extend Grids on 2nd The trace style can be set to a series of separate Monitor from the Display dialog, then choose a grid style from the Extended sample Points or a continuous vector Line.
  • Page 24: Working With Traces

    USER INTERFACE Working With Traces Adjusting Setups Trace Descriptor Boxes On setup dialogs, many entries can be made by selecting from the pop- Channel (C1-C8), Zoom (Z1-Z12), Math (F1-F12), Memory (M1-M12), up menu that appears when you touch a control. But when an entry field and Digital (Digital1-Digital4 with MSO) descriptor boxes appear along appears highlighted in blue after touching, it is active and the value can be the bottom of the grid area when a trace is turned on.
  • Page 25: Maui With Onetouch

    MAUI with OneTouch Touch, drag, swipe, pinch, and flick can be used to create and change setups with one touch. Just as you change the display by using the setup dialogs, you can change the setups by moving different display objects. Use the setup dialogs to refine OneTouch gestures to precise values. As you drag &...
  • Page 26 USER INTERFACE Copy Setups Change Source To copy the setup of one trace to another of the same type (e.g., channel to To change the source of a trace, drag-and-drop the descriptor box of the channel, math to math), drag-and-drop the source descriptor box onto the desired source onto the target descriptor box.
  • Page 27 Position Cursors Change Trigger To change cursor measurement time/level, drag cursor markers to new To change the trigger level, drag the Trigger Level indicator to a new position positions on the grid. The cursor readout will update immediately. on the Y axis. The Trigger descriptor box will show the new voltage Level. To place horizontal cursors on zooms or other calculated traces where the Horizontal Scale has forced cursors off the grid, drag the cursor readout from below the Timebase descriptor to the grid where you wish to place the...
  • Page 28 USER INTERFACE Store to Memory Scroll To store a trace to internal memory, drag-and-drop its trace descriptor box To scroll long lists of values or readout tables, swipe the selection dialog or onto the target memory (Mx) descriptor box. table in an up or down direction. Move Trace To move a trace to a different grid, drag-and-drop the trace descriptor box onto the target grid.
  • Page 29 Zoom Turn Off To create a new zoom trace, touch then drag To turn off a trace, flick the trace descriptor box toward the bottom of diagonally to draw a selection box around the the screen. portion of the trace you want to zoom. Touch the Zx descriptor box to open the zoom factor controls and adjust the zoom exactly.
  • Page 30: Front Panel

    Most of the front panel controls duplicate functionality available through the touch screen display. They are covered in more detail in the Basics section and in the HDO8000A Oscilloscopes Operator’s Manual. Below are some special front panel controls. Auto Setup turns on and configures all channels with a signal attached.
  • Page 31 BASICS HDO8000A High Definition Oscilloscopes REFERENCE...
  • Page 32: Basics

    BASICS Vertical These controls adjust the channel trace along the Y axis. From the Front Panel Analog Traces From the Display Drag another channel descriptor to the Add New box, or touch the Press Channel button to turn on Add New box and choose Channel. analog trace, or Dig button to turn on digital trace (MSO only).
  • Page 33 Digital Traces From the Display Choose a standard Choose Vertical > Digital # Setup. Logic Family, or Touch Digital descriptor to open the enter custom values Digital dialog. for Threshold and Hysteresis. Separate controls allow you to set different values for each bank.
  • Page 34: Horizontal (Timebase)

    BASICS Horizontal (Timebase) These controls adjust the trace along the X axis. From the Front Panel From the Display Turn to increase or decrease trigger Delay. Push to Touch the Timebase descriptor return Delay to zero. box to open the Timebase dialog. Turn to raise or lower Horizontal Scale (Time/div).
  • Page 35: Triggers

    From the Display Triggers tell the oscilloscope when to perform an acquisition. Available trigger types are described at more length in the Touch Trigger HDO8000A Oscilloscopes Operator’s Manual. descriptor box to open the Trigger dialog. From the Front Panel Press to open the Trigger setup dialog.
  • Page 36: Cursors

    From the Display types, each with a unique appearance on the display: Horizontal (Time), Horizontal + Vertical, Vertical (Amplitude), Horizontal (Frequency), and Horizontal (Event). These are described in more detail in the HDO8000A Oscilloscopes Operator’s Manual. From the Front Panel Press to apply cursor.
  • Page 37: Measurements & Statistics

    Measurements & Statistics Measurements are waveform parameters that can be expressed as numerical values, such as amplitude or frequency. You can set up to twelve simultaneous measurements on one or more traces and view the active readout in a table. Statistical measurements can be added to the readout, along with histicons, a miniature histogram of the statistical distribution.
  • Page 38: Math

    BASICS Math Math traces display the result of applying a mathematical function (e.g., Average, FFT, Histogram) to one or more traces. One important distinction between math functions and measurement parameters is that the result of math is always another waveform trace, whereas the result of measurement is a number.
  • Page 39: Memories (Reference Waveforms)

    Memories (Reference Waveforms) To store a new memory, either: Memories are waveform traces stored for reference. They can be recalled to the display for comparison with other traces, or they can be zoomed and measured for better analysis of historical data. You can store up to Touch the Add New box and four internal memories (M1-M12).
  • Page 40: Decode

    BASICS Decode The Decode shortcut button is activated when serial trigger and decode software options are installed. Press it to open the serial decode dialogs. Decoders apply software algorithms to extract encoded information from physical layer waveforms measured on your oscilloscope. Waveforms are annotated to provide fast, intuitive understanding of the relationship between protocol and signal.
  • Page 41: Wavescan

    WaveScan Press the WaveScan shortcut button to open the WaveScan dialogs. WaveScan Search and Find enables you to search for unusual events in a single capture, or to scan for a particular event in many acquisitions over a long period of time. A predefined set of scan modes (similar to trigger setups) enable a quick search for events of interest.
  • Page 42: Spectrum Analyzer

    BASICS Spectrum Analyzer The Spectrum shortcut button launches the Spectrum Analyzer software. Spectrum Analyzer lets you quickly and easily use the Fast Fourier Transform (FFT) for frequency analysis. The controls are the same as you would find on an RF spectrum analyzer. You set the inputs and desired frequency span, and the oscilloscope automatically generates output in units relevant to the frequency domain.
  • Page 43: History Mode

    History Mode The History front panel button puts the instrument into History Mode. History Mode allows you to review any acquisition saved in the oscilloscope’s history buffer, which automatically stores all acquisition records until full. Not only can individual acquisitions be restored to the grid, you can “scroll” backward and forward through the history at varying speeds to capture detailed changes in the waveforms over time.
  • Page 44: Q-Scape Multi-Tab Dispay

    BASICS Q-Scape Multi-Tab Display The Q-Scape shortcut button puts the oscilloscope into tabbed display mode. Press the button again to return to Normal display mode (no tabs). Also use the Q-Scape soft button on the menu bar to change the display mode.
  • Page 45: Saving And Sharing Data

    Use the oscilloscope File menu options to save and recall data. See the The current oscilloscope configuration can be saved to internal setup HDO8000A Oscilloscopes Operator’s Manual for more information on using panels or setup (.LSS) files and later recalled.
  • Page 46: Software Options

    Serial Data Mask Package (HDO8K-SDM) adds eye pattern mask testing These are just some of the options available to enhance the performance of an capability to the instrument. HDO8000A. Many Serial Trigger & Decoder Options provide added insight when debugging Advanced Customization Package (HDO8K-XDEV) supports user-defined serial data.
  • Page 47 BASICS REFERENCE HDO8000A High Definition Oscilloscopes...
  • Page 48: Reference

    1. Remove all accessories from the device. Do not include the manual. Service Centers 2. Pack the product in its case, surrounded by the original packing For a complete list of Teledyne LeCroy offices by country, including our material (or equivalent). sales and distribution partners, visit: teledynelecroy.com/support/contact 3.
  • Page 49: Certifications

    1 To ensure compliance with all applicable EMC standards, use high-quality shielded interface cables. Teledyne LeCroy certifies compliance to the following standards as of 2 Emissions which exceed the levels required by this standard may occur when the instrument is the time of publication.
  • Page 50: Safety Compliance

    For more information about proper disposal and recycling of • your Teledyne LeCroy product, please visit teledynelecroy.com/recycle. Measuring Circuit Terminals: No rated measurement category. Terminals not intended to be connected directly to the mains supply. RESTRICTION OF HAZARDOUS SUBSTANCES (RoHS) •...
  • Page 51: Warranty

    Intellectual Property The oscilloscope is warranted for normal use and operation, within All patents pertaining to the HDO8000A can be found on our website at: specifications, for a period of three years from shipment. Teledyne LeCroy will either repair or, at our option, replace any product returned to one of teledynelecroy.com/patents/...
  • Page 52 REFERENCE...
  • Page 54 928574-00 Rev A June, 2017 © 2017 Teledyne LeCroy, Inc. All rights reserved.