6.3

OPERATOR MAINTENANCE

NOTE:
The following numbers correspond to those in Figure 6-7., Oper-
ator Maintenance and Lubrication Diagram - Deutz 2.9L Engine.
Table 6-16. Lubrication Specifications
KEY
MPG
Multipurpose Grease having a minimum dripping point of 350° F (177° C). Excel-
lent water resistance and adhesive qualities, and being of extreme pressure type.
(Timken OK 40 pounds minimum.)
EPGL
Extreme Pressure Gear Lube (oil) meeting API service classification GL-5 or MIL-
Spec MIL-L-2105
HO
Hydraulic Oil. API service classification GL-3, e.g. Mobilfluid 424.
EO
Engine (crankcase). Gas (5W30)- API SN, -Arctic ACEA AI/BI, A5/B5 - API SM, SL, SJ,
EC, CF, CD - ILSAC GF-4. Diesel (15W40, 5W30 Arctic) - API CJ-4.
OGL
Open Gear Lubricant - Mobiltac 375 or equivalent.
LUBRICATION INTERVALS ARE BASED ON MACHINE OPERATION UNDER NORMAL CONDI-
TIONS. FOR MACHINES USED IN MULTI-SHIFT OPERATIONS AND/OR EXPOSED TO HOSTILE
ENVIRONMENTS OR CONDITIONS, LUBRICATION FREQUENCIES MUST BE INCREASED
ACCORDINGLY.
3121670
SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
SPECIFICATIONS
– JLG Lift –
NOTE:
It is recommended as a good practice to replace all filters at the
same time.
1. Swing Bearing - Internal Ball Bearing
Lube Point(s) - 2 Grease Fittings
Capacity - A/R
Lube - MPG
Interval - Every 3 months or 150 hours of operation
Comments - Fittings in center of bearing: Remote Access is
optional: Apply grease and rotate in 90 degree intervals
until bearing is completely lubricated
6-19