1. Turn key of Platform/Ground Select switch to
Ground.
2. Pull the Power/Emergency Stop switch to On.
3. Push the Engine Start switch until engine starts.
ALLOW ENGINE TO WARM-UP FOR A FEW MINUTES AT LOW SPEED BEFORE APPLYING
ANY LOAD.
4. After engine has had sufficient time to warm
up, push in the Power/Emergency Stop switch
and shut engine off.
5. Turn Platform/Ground Select switch to Plat-
form.
3121670
6. Pull out the Ground Console Power/Emer-
gency Stop switch to provide power to the
platform controls.
7. From Platform, pull Power/Emergency Stop
switch out.
8. Push the Engine Start switch until engine starts.
NOTE:
Footswitch must be in released (up) position before starter will
operate. If starter operates with footswitch in the depressed posi-
tion, DO NOT OPERATE MACHINE.
– JLG Lift –
SECTION 4 - MACHINE OPERATION
4-3