Removing A; Installing A; Module - Brocade Communications Systems NetIron CES 2000 Series Hardware Manual

Hide thumbs Also See for NetIron CES 2000 Series:
Table of Contents

Advertisement

Power 1 ( 3I50
Power 2: not present
Total power budget for system = 504 W
--- FANS ---
Metro fan tray (fan 1): Status = OK, Speed = MED (75%)
Metro fan tray (fan 2): Status = OK, Speed = MED (75%)
Metro fan tray (fan 3): Status = OK, Speed = MED (75%)
Metro fan tray (fan 4): Status = OK, Speed = MED (75%)
Metro fan tray (fan 5): Status = OK, Speed = MED (75%)
Metro fan tray (fan 6): Status = OK, Speed = MED (75%)
--- TEMPERATURE READINGS ---
CPU: Ambience 36.50C Chip 38.75C
24X1G PPCR: Ambience 36.0C Chip 46.62C
2X10G PPCR: Ambience 37.0C Chip 42.18C
Fans are in auto mode. Temperature Monitoring Poll Period is 60 seconds
--- MISC INFO ---
Backplane EEPROM MAC Address:
NetIron>
Syntax: show chassis
Installing or Replacing a 10-Gigabit Ethernet Module
The 2-port 10-Gigabit Ethernet modules may optionally be installed or replaced in the field on the NetIron CES
2024C and NetIron CES 2024F units. You can order the NetIron CES 2000 Series with a 2 x10-Gigabit module
installed at the factory, or you can later upgrade your device.
This section provides the steps for installing, removing, and replacing the 10-Gigabit Ethernet module. You will
need the following tools to perform these procedures:
#2 Phillips-head screwdriver
Electrostatic Discharge (ESD) kit
NOTE: For safety reasons, the ESD wrist strap should contain a series 1 meg ohm resistor
Removing a 2 x10-Gigabit Ethernet Module
1.
Power off the NetIron CES 2000 device.
2.
Use a #2 Phillips-head screwdriver to loosen the screws on the 2 x10-Gigabit module.
3.
Remove the 2 x10-Gigabit module.
4.
Place the 2 x10-Gigabit module in an anti-static bag for storage.
5.
If you are removing the module without replacing it, install the blank faceplate in the front panel.
Installing a 2 x10-Gigabit Ethernet Module
Follow these procedures when installing a 10-Gigabit Ethernet Module:
1.
Power off the NetIron CES 2000 device.
2.
Use a #2 Phillips-head screwdriver to remove the blank faceplate or old module from the front panel.
3.
Install the 10-Gigabit module in the chassis.
4.
Use a #2 Phillips-head screwdriver to fasten the screws on the 2 x10-Gigabit module. Affix the screws loosely
at first, then tighten them once you are sure the board is properly positioned.
March 2009
- AC 504W): Installed (OK)
0001.0040.7800
© 2009 Brocade Communications Systems, Inc.
Maintaining the Hardware
6 - 5

Advertisement

Table of Contents
loading

Table of Contents