Removing an AC Power Supply
1.
Unplug the power supply from the power source.
2.
Disconnect the power cord from the power supply.
3.
If necessary, remove the power supply locking screw located in the left rear of the device.
4.
Hold the bar on the front panel of the power supply and pull outward. This will disconnect the power supply
from the backplane.
5.
Continue to pull the power supply until it is removed from the device.
6.
Place the power supply in an anti-static bag for storage.
7.
Insert a new supply, or place the cover plate over the empty power supply.
8.
Replace the power supply locking screw.
Installing an AC Power Supply
To install an AC power supply, do the following:
1.
If necessary, remove the power supply locking screw located on the upper right quadrant and the lower left
quadrant of the power supply (illustrated below).
Power Supply Locking Screws
2.
If the empty power supply bay has a cover plate, remove the two screws near the edges of the cover plate to
unlock the plate, then remove the plate.
3.
Remove the power supply from its packaging.
4.
With one hand, hold the bar on the front panel of the power supply. With the other hand, support the
underside of the power supply, and insert the power supply into the empty power supply slot. Press until the
supply is completely in the slot, so that the connectors on the back of the supply are fully engaged with the
pins on the power backplane.
CAUTION: Make sure you insert the power supply right-side up. It is possible to insert the supply upside
down, although the supply will not engage with the power backplane when upside down. The power supply is
right-side up when the power connector is on the left and the fan vent is on the right.
5.
Insert the two locking screws near the edges of the supply and tighten to lock the supply in place.
6.
Connect the power cord to the power supply.
7.
Connect the plug end of the power cord into an outlet.

Verifying Proper Operation

To verify the proper operation of the power supply after power on, you can observe the LEDs on the power supply.
After the NetIron CES and CER 2000 Series devices device powers on, you can observe the LEDs on the front of
the device to verify that it initialized successfully. Table 6.1 outlines the LEDs, the desired state of each LED,
possible abnormal states of each LED, and what to do if an LED indicates an abnormal state.
March 2009
© 2009 Brocade Communications Systems, Inc.
Maintaining the Hardware
6 - 3