ISCSI TLV Tx Status is disabled
Local FCOE PriorityMap is 0x8
Local ISCSI PriorityMap is 0x10
Remote FCOE PriorityMap is 0x8
Remote ISCSI PriorityMap is 0x8
0 Input TLV pkts, 1 Output TLV pkts, 0 Error pkts, 0 Pause Tx pkts, 0 Pause Rx pkts
The following table describes the show interface pfc summary command fields.
Table 21. show interface pfc summary Command Description
Fields
Interface
Admin mode is on; Admin is enabled
Remote is enabled; Priority list Remote Willing Status is enabled
Local is enabled
Operational status (local port)
PFC DCBx Oper status
State Machine Type
TLV Tx Status
PFC Link Delay
Application Priority TLV: FCOE TLV Tx Status
Application Priority TLV: ISCSI TLV Tx Status
Application Priority TLV: Local FCOE Priority Map
Description
Interface type with stack-unit and port number.
PFC Admin mode is on or off with a list of the configured PFC
priorities . When PFC admin mode is on, PFC advertisements are
enabled to be sent and received from peers; received PFC
configuration takes effect. The admin operational status for a DCBx
exchange of PFC configuration is enabled or disabled.
Operational status (enabled or disabled) of peer device for DCBx
exchange of PFC configuration with a list of the configured PFC
priorities. Willing status of peer device for DCBx exchange (Willing
bit received in PFC TLV): enabled or disabled.
DCBx operational status (enabled or disabled) with a list of the
configured PFC priorities
DCBx operational status (enabled or disabled) with a list of the
configured PFC priorities.
Port state for current operational PFC configuration:
Init: Local PFC configuration parameters were exchanged with
peer.
Recommend: Remote PFC configuration parameters were
received from peer.
Internally propagated: PFC configuration parameters were
received from configuration source.
Operational status for exchange of PFC configuration on local port:
match (up) or mismatch (down).
Type of state machine used for DCBx exchanges of PFC
parameters:
Feature: for legacy DCBx versions
Symmetric: for an IEEE version
Status of PFC TLV advertisements: enabled or disabled.
Link delay (in quanta) used to pause specified priority traffic.
Status of FCoE advertisements in application priority TLVs from
local DCBx port: enabled or disabled.
Status of ISCSI advertisements in application priority TLVs from
local DCBx port: enabled or disabled.
Priority bitmap used by local DCBx port in FCoE advertisements in
application priority TLVs.
Data Center Bridging (DCB)