Technical Data - KROHNE WATERFLUX 3070 Handbook

Battery powered electromagnetic water meter with optional krohne flexpower
Hide thumbs Also See for WATERFLUX 3070:
Table of Contents

Advertisement

TECHNICAL DATA

8
8.2 Technical data
INFORMATION!
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Downloadcenter).
Measuring system
Measuring principle
Application range
Measured value
Measured value
Measured value
Measured value
Primary measured value
Secondary measured value
Optional measured value
Design
Features
Modular construction
Compact version
Remote version
Nominal diameter
Display and user interface
Display and user interface
Display and user interface
Display and user interface
Display
Operation
Display information
Optional:
Remote reading
70
Faraday's law of induction
Electrically conductive fluids
Flow velocity
Volume flow
Pressure and temperature
Unique rectangular flow tube design providing improved flow profile and
signal to noise ratio resulting in highest accuracy, low energy consumption
and large turndown ratio
®
Rilsan
polymer coated flow tube approved for drinking water
No internal or moving parts
Built-in reference electrode
Optional; built-in P&T sensor (restricted to DN50...200), refer to
P&T sensor (optional)
on page 76
Self-providing energy by batteries for up to 10 years
The measurement system consists of a flow sensor and a signal converter.
It is available as a compact and as a remote version.
With IFC 070 converter: WATERFLUX 3070 C
In field (F) version with IFC 070 converter: WATERFLUX 3070 F
Cable length up to 25 m / 70 ft, other lengths on request
DN25...600 / 1...24", Rectangular bore
LCD display, 8 digits
2 optical keys to navigate through the menu of the signal converter without
opening the housing.
Standard:
Standard:
Standard:
Standard:
Sum counter (default), forward counter, reverse counter or flow rate
Flow direction (forward or reverse), counter settings
Measured value and measuring unit
Battery lifetime indicator
Operating pressure, operating temperature, empty pipe, self-test, display
test, test mode, diameter, meter constant, software version, AMR mode,
warning sign, multiplier
Optional: external GSM / GPRS data logger for pulse or Modbus
For preselected data logger brands, please contact KROHNE
www.krohne.com
WATERFLUX 3070
06/2016 - 4004999701 - MA WATERFLUX 3070 - R01 en