• If you need to return the device to the manufacturer or supplier, please fill out the form contained in the manual and send it with the device. Unfortunately, the manufacturer cannot repair or inspect the device without the completed form. www.krohne.com 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en...
• Remove the battery from device before returning to the manufacturer for service or warranty reasons. • Dispose battery packs in accordance with local regulations; where possible, recycle used batteries. 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
The signal converter housing is delivered with attached IP67 dust caps to protect the connections of the signal converter. After removing the caps and connecting the signal- and sensor cables, the signal converter housing and connections are IP68 rated. www.krohne.com 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en...
Product specific information and extensive product specification is available using PICK, the Product Information Center KROHNE web-tool. PICK can be found via the service menu button on the KROHNE.com website. The following versions are available: • Compact version (the signal converter is mounted directly on the measuring sensor) in polycarbonate (IP68) housing •...
8 Meter constant, diameter, wetted materials, protection class 9 Type designation of the flowmeter, serial number, date of manufacturing (option: text P&T only for versions with integrated pressure and temperature sensor) www.krohne.com 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en...
• Allen key (4 mm) • Small screwdriver • Wrench for cable glands (remote version only) • Wrench for wall mounting bracket (remote version only) • Torque wrench for installing flowmeter in pipeline 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
"Technical data" in the manual and the technical documentation. • Avoid magnetic field! Keep at least 5 DN distance between electromagnetic flow sensors. 2.7.1 Vibration Figure 2-5: Avoid vibrations 2.7.2 Magnetic field Figure 2-6: Avoid magnetic fields www.krohne.com 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en...
2 Outlet: 0 DN 2.8.2 T-section Figure 2-8: Distance behind a T-section 1 0 DN 2.8.3 Open feed or discharge Figure 2-9: Installation in front of an open discharge 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
CAUTION! Avoid draining or partial filling of the flow sensor. INFORMATION! Vertical installation on a descending slope in the pipeline is only recommended when the back- pressure is controlled. www.krohne.com 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en...
Recommended position to install a flowmeter is upstream a control valve. An electromagnetic flowmeter can be installed downstream of the control valve if there is no cavitation in the pipeline system (e.g. flow profile disturbances are resolved). 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
• Mount flow sensor either with the signal converter aligned upwards or downwards. • Install flow sensor in line with the pipe axis. • Pipe flange faces must be parallel to each other. 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
In applications with prolonged or continuous submersion, it is advised to use the WATERFLUX 3070 remote version. The remote IFC 070 signal converter and GPRS data logger unit can be installed on the wall of the measuring pit near the lid for visual read out of the display.
• Step 1: Apply approx. 50% of max. torque given in table. • Step 2: Apply approx. 80% of max. torque given in table. • Step 3: Apply 100% of max. torque given in table. 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
Page 18
1 The torque values also depend on variables (temperature, bolt material, gasket material, lubricants, etc.) outside the control of the manufacturer. Therefore these values should be regarded as indicative only. 2 No full rating (max. 10 bar) www.krohne.com 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en...
Page 19
1 The torque values also depend on variables (temperature, bolt material, gasket material, lubricants, etc.) outside the control of the manufacturer. Therefore these values should be regarded as indicative only. 2 No full rating (max. 150 psi / 10 bar). 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
2 are inline (do not tighten the ring any further). • Use the special wrench to tighten the ring as advised above. • If applicable, place a new utility seal (see section Utility Seal). www.krohne.com 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en...
Mounting on the pipe line construction can easily be done by using 2 Tie-Wraps. The bottom of the housing of the KROHNE FlexPower unit is designed for mounting on a pipe line. Choose the correct size and properties of the Tie-Wraps (specifications according ambient temperature and other conditions, size, width max.14 mm / ½").
Check for the correct supply voltage printed on the nameplate. 3.2 Grounding Figure 3-1: Grounding INFORMATION! Grounding without grounding rings. The flow sensor is equipped with a reference electrode. www.krohne.com 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en...
The flow sensor cable for the IP68 remote (field) version has an 8 pin male connector. The I/O cable (pulse /modbus) is available in a KROHNE FlexPower version and has an additional power cable connection. Overview I/O cables, with or without a power cable, with female connector:...
For the WATERFLUX 3070 remote version, a standard cable is delivered with the device. On the flow sensor side the cable is as standard potted at the factory. The flow sensor cable has a IP68...
Up link wire A Sign. A (D0-) Green Down link wire A (D0-) White Ground Brown Shield Earth Note: see the next chapter for the combined power and modbus / pulse cable options. 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
Up link wire B Sign. B (D1+) Grey Pink Up link wire A Sign. A (D0-) Green Down link wire A Sign. A (D0-) White Ground Brown Shield Earth www.krohne.com 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en...
Page 27
For proper use and installation, it is recommended to follow the advised color coded wire connections in the table above. A 120 line terminator is required when the WATERFLUX 3070 signal converter is the last device in line and/or is part of the bus connection.
For information on the different battery types refer to Types of batteries on page 28. INFORMATION! The device now operates with default menu settings. For configuration of these menu settings refer to Battery settings on page 30. 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
For more information regarding the battery menu settings refer to Battery settings on page 30. 4.4 Power supply - battery The standard version of the WATERFLUX 3070 has an internal battery pack with a Lithium double D cell (3.6V-38 Ah). Optional an KROHNE PowerBlock (Lithium Dual DD cell 3.6V-70 Ah) can be connected with an IP68 rated, 1.5 meter long cable.
Beside regular battery power supplies, the WATERFLUX 3070 can also be connected to an external KROHNE FlexPower unit. The external KROHNE FlexPower unit has an internal Lithium battery pack (3.6 V -38 Ah) and can be connected with a combined power and output cable (Y-cable) for power input. The unit is delivered with a special power cable for connection to a 10...30 V DC supply (a.o.
Take measures to prevent water ingress and shock hazard on AC and/or DC cables when not connected. Optionally, beside an internal or external battery, the WATERFLUX 3070 can be connected to an external FlexPower unit for mains power and/or DC power operation with battery back-up.
Page 33
Yellow/Green FE (functional earth) AC power cable (grey cable) Wire color Connection Black 1 AC (~) Black 2 AC (~) Green/Yellow PE (protective earth) Cable Ø = 0.75 mm 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
= 159 mm / 6.3" polycarbonate housing b = 161 mm / 6.3" (IP68) Total height = H + a 1 The value may vary depending on the used cable glands. www.krohne.com 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en...
Page 35
• Note that for other pressure ratings than mentioned, the dimensions may be different. • For full information on signal converter dimensions see relevant documentation. EN 1092-1 Nominal size Dimensions [mm] Approx. weight DN [mm] [kg] 03/2022 - 4005303003 - QS WATERFLUX 3070 - R03 en www.krohne.com...
Page 40
Engineering, commissioning, calibration, maintenance and training services Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 47058 Duisburg (Germany) Tel.: +49 203 301 0 Fax: +49 203 301 10389 info@krohne.de The current list of all KROHNE contacts and addresses can be found at: www.krohne.com...
Need help?
Do you have a question about the WATERFLUX 3070 and is the answer not in the manual?