S600+ Instruction Manual
7.4.1 Network Setup
Ethernet LAN
Caution
7-4
Option
Reflash Firmware
Factory Setup
This option on the Startup menu enables you to define the TCP/IP
Ethernet, Gateway, and Modbus network addresses.
: Determine the necessary network settings before you initiate
Note
any network communications. You can only view or modify
these settings physically through the Startup menu. (You
cannot use the Config600 software to define communications.)
The S600+ keeps these settings in a separate area of the SRAM
database and retains them after you download a configuration
file to the S600+.
Before you establish an Ethernet LAN connection (for host
communications, local operator communications, or web server
access), you must verify or define the TCP/IP address.
: This process requires that you first access the Startup menu
Note
To define the Ethernet LAN network address:
Select NETWORK SETUP from the Startup menu. The Network
1.
Setup menu displays:
1* NETWORK 1 I/F
2* NETWORK 2 I/F
4. MODBUS ADDRESS
5. PC SETUP COMMS
6. WEBSERVER SETUP
7. GO BACK
Figure 7-3. Network Startup Menu
While NTWK1 and NTWK2 may have different unique TCP/IP and
subnet mask values, you can only define one default gateway.
Select either NETWORK I/F 1 or NETWORK I/F 2. A
2.
connection-specific menu displays:
Startup
Description
Reprograms the S600+ operating system
firmware stored in Flash memory (see
Chapter 8, Troubleshooting).
Clears SRAM and formats Flash memory and
changes additional settings.
Note: Use this option only at the direction of
a factory representative.
Revised July-2017