S600+ Instruction Manual
C.10.3 Reports
C-24
The following table shows the composition settings\information and
chromat settings:
Screen
Definition
Mole Select
Controls which composition is used in the calculations
and is also what displays under the "Selected Moles"
display.
Choices for the mole selection are:
Acceptance
Accepts an updated composition when the analysis
Command
changes so that it is copied in to the selected moles.
When the Chromat option is selected and if the new
analysis is okay, the acceptance is automatically
triggered.
Note: When Keypad, Download or User composition is
selected, this has to be triggered manually either from the
display or by setting the flag via Modbus or Liogicalc.
Keypad Moles
There are 14 screens which list the values for the keypad
moles. Each of these values can be modified from the
front panel or web server. The total of all the components
is summarised on the last keypad moles screen.
Selected
There are 14 screens which list the values for the
Moles
selected moles. These values cannot be modified and
represent the composition that is being used in the
calculations.
Telem Stage
Indicates the current stage for the chromat task.
Telem Poll
Specifies the time in seconds to wait between issuing
Delay
polls to the chromat.
Telem Reset
Delay before issuing a reset of the new data flag after a
Delay 1
new analysis has been received and processed.
Telem Reset
Delay before issuing a reset of the new data flag after a
Delay 2
new analysis has been received and processed but the
cycle streams do not match, for example on an analysis
for stream 1 was expected but the chromat indicated the
analysis was for stream 2.
D/Load
Defines a timeout which, when expired, raises an alarm to
Timeout
indicate that the chromat has not provided a new analysis
in time.
By default, when you select a chromatograph, the system does not
automatically add these reports. You must manually add them.
To configure chromatograph reports, select System Setup > Reports.
The General Reports screen displays.
Chromatographs
Keypad: Uses the moles under the "Keypad Moles"
displays
Chromat: Uses the analysis from the chromat
Download: Uses an analysis downloaded to the
S600+ from an external supervisory system or PLC
User: Uses a user supplied keypad real array of
composition data.
Revised July-2017