Table of Contents

Advertisement

T80si electric shower

OPERATING FUNCTIONS

OPERATInG FunCTIOnS
Fig.
Power on indicator
(fig.)
Power 'ON' Indicator
When the electricity supply to the shower is
switched on at the isolating switch, the 'power'
indicator will light.
Low pressure indicator
(fig.)
A red indication means the water pressure has
fallen below the minimum required for correct
operation of the shower. In this state the low
pressure cut-out has operated. This switches
off power to the heating elements preventing
undue temperature rises (water will continue to
flow). Power will automatically be restored when
adequate water pressure returns.
If the indication fluctuates between red and
green, this means that there is just enough
Low pressure indicator
pressure and operating difficulties may be
encountered.
A green indication shows that water pressure
is high enough for satisfactory operation of the
shower.
overheat cut-out
During normal operation if an overheat
temperature is sensed, power to the elements
will be reduced. Water will continue to flow.
When the temperature has cooled sufficiently,
power to the elements will be automatically
restored to the previous setting at the time of
interruption.
Safety cut-out
The unit is fitted with a non-resettable over-
temperature safety device. In the event of
abnormal operation which could cause unsafe
temperatures within the unit, the device will
disconnect the heating elements. It will require a
visit from a qualified engineer to determine the
nature of the fault and replace the safety device,
once the unit has been repaired.