Operating Functions - Triton Ivory 2 Installation And Operating Instructions Manual

Electric shower
Table of Contents

Advertisement

Operation

OPERATING FUNCTIONS

Fig.34
Power on indicator (fig.34)
When the electricity supply to the shower is
switched on at the isolating switch, the 'power'
indicator will light. Note however, that should
Power on
indicator
the safety cut-out device operate, the indicator
will remain lit.
Low water pressure cut-out
If the water pressure falls below the minimum
required for correct operation of the shower,
power will be switched off to the heating
elements preventing any maintained
temperature rises (water will continue to flow).
Power will automatically be restored when
adequate water pressure returns.
Temperature limiter
During normal operation if an overheat
temperature is sensed, power to the elements
will be reduced. Water will continue to flow.
When the temperature has cooled sufficiently,
power to the elements will be automatically
restored to the previous setting at the time of
interruption.
Safety cut-out
The unit is fitted with a non-resettable thermal
cut-out safety device. In the event of abnormal
operation which could cause unsafe
temperatures within the unit, the device will
disconnect the heating elements. It will require
a visit from a qualified engineer to determine
the nature of the fault and replace the safety
device, once the unit has been repaired.
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents