OPERATING FUNCTIONS

Operating functions
There will always be a time delay of a few
seconds between selecting a temperature
and the water reaching the stable selected
temperature.
Low pressure
When the low pressure indicator (fig.26)
flashes steadily (the Care Plus will also 'bleep'
intermittently) it means the water pressure has
fallen below the minimum pressure required
for correct operation of the shower, resulting in
the low pressure switch operating. This switches
off power to the heating elements preventing
any maintained temperature rises. Water will no
longer flow until the unit has been reset.
Press the START/STOP button once to reset the
shower. The low pressure light will go out and
the unit will now be ready for normal operation.
Once normal water pressure is restored, the unit
can be restarted by pressing the START/STOP
button.
Phased shutdown
In use, when the START/STOP button is pressed,
power is switched off to the elements and the
power indicator will extinguish. Water continues
to flow for a few seconds, flushing out any
remaining hot water. This makes sure that the
next immediate user will not receive a slug of
hot water if standing under the showerhead
when starting the shower.
Safety cut-out
The shower is fitted with a thermal cut-out safety
device. In the event of abnormal operation
which could cause unsafe temperatures within
the unit, the device will disconnect the heating
elements.
It will require a visit from a qualified engineer to
find out the nature of the fault and replace the
safety device, once the unit has been repaired.
Note: In normal use, it is normal to leave the
water supply permanently on to the shower unit,
but as with most electrical appliances, the unit
should be switched off at the isolating switch
when not in use.