Front Control Panel Pin Definitions; Power Led; Hdd Led; Power Fail Led - Supermicro X10SRG-F User Manual

Table of Contents

Advertisement

Front Control Panel Pin Definitions

Power LED

The Power LED connection is located
on pins 15 and 16 of JF1. Refer to the
table on the right for pin definitions.

HDD LED

The HDD LED connection is located
on pins 13 and 14 of JF1. Attach a
cable here to indicate the status of
HDD-related activities, including IDE,
SATA activities. See the table on the
right for pin definitions.

Power Fail LED

The Power Fail LED connection is
located on pins 5 and 6 of JF1. Refer
to the table on the right for pin defini-
tions.
A. PWR LED
B. HDD LED
C. PWR Fail LED
Ground
Power LED
A
B
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
C
Power Fail LED
20
19
X
Ground
Ground
2
1
2-19
Power LED
Pin Definitions (JF1)
Pin#
Definition
15
+5V
16
Ground
HDD LED
Pin Definitions (JF1)
Pin#
Definition
13
+5V
14
HD Active
PWR Fail LED
Pin Definitions (JF1)
Pin#
Definition
5
Vcc
6
Ground
NMI
X
P3V3
UID SW
P3V3_STB
P3V3_STB
UID LED
P3V3
Reset
Reset Button
Power Button
PWR
Chapter 2: Installation
Power LED
Status
State
Definition
Off
System Off
On
System Running
HDD LED
Status
State
Definition
Off
No Activity
Blinking
HDD Busy
Power Fail LED
Status
State
Definition
Off
Normal
On
Power Failure

Advertisement

Table of Contents
loading

Table of Contents