Supermicro X10SRL-F User Manual
Hide thumbs Also See for X10SRL-F:
Table of Contents

Advertisement

Quick Links

X10SRL-F
USER'S MANUAL
Revision 1.2b

Advertisement

Table of Contents
loading

Summary of Contents for Supermicro X10SRL-F

  • Page 1 X10SRL-F USER’S MANUAL Revision 1.2b...
  • Page 2 This product, including software and docu- mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
  • Page 3 ® Server Platform Services (Intel SPS), offering great system enhancement to high performance storage platforms. Please refer to our website (http://www.supermicro.com/products/) for processor and memory support updates. This product is intended to be installed and serviced by professional technicians. Manual Organization...
  • Page 4 X10SRL-F User’s Manual Conventions Used in the Manual: Special attention should be given to the following symbols for proper system instal- lation: Warning: Critical information given to prevent damage to the components or injury to yourself. Note: Additional Information provided for correct system setup.
  • Page 5 Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 6: Table Of Contents

    X10SRL-F User’s Manual Table of Contents Preface Chapter 1 Introduction Overview ......................1-1 Checklist ......................1-1 Motherboard Features ..................1-7 Chipset Overview ..................1-10 Special Features ....................1-11 PC Health Monitoring ..................1-11 ACPI Features ....................1-12 Power Supply ....................1-12 Chapter 2 Installation Standardized Warning Statements ..............
  • Page 7 Table of Contents Front Control Panel ..................2-21 Front Control Panel Pin Definitions............... 2-22 NMI Button ....................2-22 Power LED ....................2-22 HDD LED ....................2-23 NIC1/NIC2 LEDs ..................2-23 Overheat (OH)/Fan Fail/PWR Fail/UID LED ..........2-24 Power Fail LED ..................2-24 Reset Button ...................
  • Page 8 X10SRL-F User’s Manual Chapter 3 Troubleshooting Troubleshooting Procedures ................3-1 Before Power On .................... 3-1 No Power ......................3-1 No Video ......................3-2 Memory Errors ....................3-2 Losing the System’s Setup Configuration ............3-2 Technical Support Procedures ................ 3-3 Frequently Asked Questions ................3-4 Battery Removal and Installation ..............
  • Page 9 Table of Contents Appendix D Dual Boot Block on Grantley Platforms Overview ........................D-1 Before Startup ......................D-1 When to Use Dual Boot Block ...................D-1 How to Use Dual Boot Block..................D-1 IPMI GUI Browser ...................D-2 IPMI Command Sets ..................D-7 User Approach ......................D-9...
  • Page 10 X10SRL-F User’s Manual Notes...
  • Page 11: Chapter 1 Introduction

    Checklist Congratulations on purchasing your computer motherboard from an acknowledged leader in the industry. Supermicro boards are designed with the utmost attention to detail to provide you with the highest standards in quality and performance. Please check that the following items have all been included with your motherboard.
  • Page 12 X10SRL-F User’s Manual X10SRL-F Motherboard Image Note: All graphics shown in this manual were based upon the latest PCB Revision available at the time of publishing of the manual. Your motherboard or components may or may not look exactly the same as the graphics shown in this manual.
  • Page 13 Chapter 1: Introduction X10SRL-F Motherboard Layout UID LED - LE1 COM1 UID - SW USB2/3(3.0) USB0/1 FAN5 IPMI_LAN LAN2 LAN1 LEDM1 JPL2 CTRL JVR1 JPL1 CTRL USB4/5 USB6/7 USB8/9 JBT1 JIPMB1 X10SRL-F IPMI Rev: 1.01 DESIGNED IN USA BAR CODE...
  • Page 14 5V STBY T-SGPIO3 T-SGPIO2 JOH1 T-SGPIO1 USB10(3.0) FAN4 FAN3 USB11(3.0) FAN2 FANA I-SATA3 I-SATA2 I-SATA1 I-SATA0 FAN1 X10SRL-F PCIe Lanes Configuration Table PCIe Slot# Configuration-1 Configuration-2 Slot-7 (next to memory) Slot-6 Slot-5 Slot-4 Slot-3 Slot-2 Slot-1 (next to board edge)
  • Page 15 Chapter 1: Introduction Jumper Description Default JBR1 BIOS Recovery Pins 1-2 (Normal) JBT1 CMOS Clear See Chapter 2 C1/JI SMB to PCI-E Slots Pins 2-3 (Disabled) JPB1 BMC Enable/Disable Pins 1-2 (Enabled) JPG1 VGA Enable Pins 1-2 (Enabled) JPL1/JPL2 LAN1/LAN2 Enable Pins 1-2 (Enabled) JPME2 Manufacture Mode Select...
  • Page 16 X10SRL-F User’s Manual USB 4/5, 6/7, 8/9 Front Panel Accessible USB 2.0 Headers USB 10, 11 Front Panel Accessible USB 3.0 Ports Back panel VGA Port Description State/Color Status UID LED Blue: On Unit Identified Onboard PWR LED Green: On...
  • Page 17: Motherboard Features

    Chapter 1: Introduction Motherboard Features Single Intel ® E5-2600/1600 Series processor in an LGA2011 R3 socket. Note: Both E5-2600v4 and E5-1600v4 re- quire Revision 2.0 BIOS (or higher). Memory Eight (8) ECC DDR4 RDIMM/LRDIMM at 2400 MHz (max.) memory (1 DPC) up to 256GB RDIMM or 512GB LRDIMM. Dual-channel memory DIMM sizes RDIMM...
  • Page 18 X10SRL-F User’s Manual Network One i210 Dual Channel Gigabit (100/1000 MB/s) Ethernet Contoller for LAN 1/LAN 2 ports BIOS 128 Mb AMI BIOS SPI Flash BIOS ® Plug and Play (PnP), DMI 2.3, PCI 2.3, ACPI 1.0/2.0/3.0, USB Keyboard and SMBIOS 2.5 Power Configuration APM 1.2, APCI 2.3, ACPI 1.0/2.0/3.0/4.0, USB Keyboard,...
  • Page 19 Chapter 1: Introduction X10SRL-F Block Diagram VR12.5 5 PHASE 145W DMI2 2C/D 2A/B 3C/D 3A/B PCIe3.0 x8 SLOT6 PCIe3.0 x16 PCIe3.0 x4 PCIe3.0 x8 PCIe3.0 x8//x4 SLOT7 PCIe3.0 x8 SLOT3 PCIe3.0 x8 PCI-E PCIe3.0 x4 PCIe3.0 x0//x4 SWITCH SLOT2 PCIe3.0 x8 PCIe3.0 x8...
  • Page 20: Chipset Overview

    Direct Media Interface (DMI) for chip-to-chip true isochronous communication, providing up to 5 GT/s of software-transparent data transfer rate on each read/write direction. In addition, the X10SRL-F also features a TCO timer which allows the system to recover from a software/hardware lock and perform tasks, including Function Disable and Intruder Detect.
  • Page 21: Special Features

    Chapter 1: Introduction Special Features Recovery from AC Power Loss Basic I/O System (BIOS) provides a setting for you to determine how the system will respond when AC power is lost and then restored to the system. You can choose for the system to remain powered off, (in which case you must press the power switch to turn it back on), or for it to automatically return to a power-on state.
  • Page 22: Acpi Features

    X10SRL-F User’s Manual ACPI Features ACPI stands for Advanced Configuration and Power Interface. The ACPI specifica- tion defines a flexible and abstract hardware interface that provides a standard way to integrate power management features throughout a PC system, including its hardware, operating system and application software. This enables the system to automatically turn on and off peripherals such as CD-ROMs, network cards, hard disk drives and printers.
  • Page 23: Chapter 2 Installation

    The following statements are industry-standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assis- tance. Only certified technicians should attempt to install or configure components.
  • Page 24 X10SRL-F User’s Manual Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant. ¡Advertencia! Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Re- emplazar la batería exclusivamente con el mismo tipo o el equivalente recomen-...
  • Page 25: Product Disposal

    Chapter 2: Installation Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations. 製品の廃棄 この製品を廃棄処分する場合、 国の関係する全ての法律 ・ 条例に従い処理する必要が あり ます。 警告 本产品的废弃处理应根据所有国家的法律和规章进行。 警告 本產品的廢棄處理應根據所有國家的法律和規章進行。 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen.
  • Page 26: Static-Sensitive Devices

    X10SRL-F User’s Manual ‫القىانين واللىائح الىطنية‬ ‫جميع‬ ‫وفقا ل‬ ‫ينبغي التعامل معه‬ ‫هذا المنتج‬ ‫من‬ ‫التخلص النهائي‬ ‫عند‬ 경고! 이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다. Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen.
  • Page 27: Motherboard Installation

    USB0/1 FAN5 LAN2 LAN1 IPMI_LAN LEDM1 JPL2 CTRL JVR1 JPL1 CTRL USB4/5 USB6/7 USB8/9 JBT1 JIPMB1 X10SRL-F IPMI Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 BIOS LICENSE JSD2 JWD1 MAC CODE S-SATA3 JSTBY1 S-SATA2...
  • Page 28: Installing The Motherboard

    X10SRL-F User’s Manual Installing the Motherboard 1. Install the I/O shield into the back of the chassis. 2. Locate the mounting holes on the motherboard. (See the previous page.) 3. Locate the matching mounting holes on the chassis. Align the mounting holes on the motherboard against the mounting holes on the chassis.
  • Page 29: Processor And Heatsink Installation

    CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro website for updates on CPU support. Installing the LGA2011 Processor 1. There are two load levers on the LGA2011 socket. To open the socket cover, first press and release the load lever labeled 'Open 1st'.
  • Page 30 X10SRL-F User’s Manual 2. Press the second load lever labeled 'Close 1st' to release the load plate that covers the CPU socket from its locking position. Press down on Load Pull lever away from Lever 'Close 1st' the socket 3. With the lever labeled 'Close 1st' fully retracted, gently push down on the lever labelled 'Open 1st' to open the load plate.
  • Page 31 Chapter 2: Installation 4. Using your thumb and the index finger, remove the 'WARNING' plastic cap from the socket. 5. Using your thumb and index finger, hold the CPU on its edges. Align the CPU keys, which are semi-circle cutouts, against the socket keys. Socket Keys CPU Keys 6.
  • Page 32 X10SRL-F User’s Manual 7. With the CPU inside the socket, inspect the four corners of the CPU to make sure that the CPU is properly installed. 8. Close the load plate with the CPU inside the socket. Lock the lever labelled 'Close 1st' first, then lock the lever labelled 'Open 1st' second.
  • Page 33: Installing A Passive Cpu Heatsink

    Chapter 2: Installation Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die -- the re- quired amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the Motherboard's and the Heatsink Bracket under- neath.
  • Page 34: Removing The Heatsink

    X10SRL-F User’s Manual Removing the Heatsink Warning: We do not recommend that the CPU or the heatsink be removed. However, if you do need to uninstall the heatsink, please follow the instructions below to prevent damage to the CPU or the CPU socket.
  • Page 35: Installing Ddr4 Memory

    Chapter 2: Installation Installing DDR4 Memory Note: Check the Supermicro website for recommended memory mod- ules. CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Installing Memory Modules UID LED - LE1 UID - SW COM1 USB2/3(3.0)
  • Page 36: Removing Memory Modules

    DIMMC1 DIMMA1 The X10SRL-F supports eight ECC DDR4 RDIMM/LRDIMM at 2400 MHz (max.) memory (1 DPC) up to 256GB RDIMM or 512GB LRDIMM. Populating these DIMM modules with a pair of memory modules of the same type and size will result in interleaved memory, which will improve memory performance.
  • Page 37 Chapter 2: Installation Populating RDIMM/LRDIMM DDR4 Memory Modules for the E5- 2600v3-based Motherboard Speed (MT/s); Voltage (V); Slot Per Channel (SPC) and DIMM Per Channel (DPC) DIMM Capacity Ranks Per (GB) DIMM and Type 1 Slot Per Data 2 Slots Per Channel Channel Width 1DPC...
  • Page 38 X10SRL-F User’s Manual Notes: • Be sure to use memory modules of the same type and speed on the same motherboard. Mixing of memory modules of different types and speeds is not allowed. • Due to memory allocation to system devices, the amount of memory that remains available for operational use will be reduced when 4 GB of RAM is used.
  • Page 39: Connectors/Io Ports

    FAN5 IPMI_LAN LAN2 LAN1 JPL2 LEDM1 CTRL JVR1 JPL1 CTRL USB4/5 USB6/7 USB8/9 JBT1 JIPMB1 IPMI X10SRL-F Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 BIOS LICENSE JSD2 JWD1 MAC CODE S-SATA3 JSTBY1 S-SATA2 5V STBY...
  • Page 40: Universal Serial Bus (Usb)

    X10SRL-F User’s Manual Universal Serial Bus (USB) Four Universal Serial Bus ports (USB 3.0 ports 2/3 and USB 2.0 ports 0/1) are located on the I/O back panel. In addition, three USB 2.0 headers (USB 4/5, 6/7, 8/9), and two USB 3.0 connectors (USB 10, USB 11) are also located on the motherboard to provide USB 3.0 support using USB cables (not included).
  • Page 41: Ethernet Ports

    USB0/1 LAN2 LAN1 IPMI_LAN LEDM1 JPL2 E. COM2 CTRL JVR1 JPL1 CTRL USB4/5 USB6/7 USB8/9 JBT1 JIPMB1 X10SRL-F IPMI Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 JSD2 BIOS LICENSE JWD1 MAC CODE S-SATA3 JSTBY1...
  • Page 42: Unit Identifier Switch/Uid Led Indicator

    X10SRL-F User’s Manual Unit Identifier Switch/UID LED Indicator UID Switch A Unit Identifier (UID) switch and an LED Pin# Definition Indicator are located on the motherboard. Ground The UID switch is located next to the VGA Ground port on the back panel. The UID LED (LE1) Button In is located next to the UID switch.
  • Page 43: Front Control Panel

    These connectors are designed spe- cifically for use with Supermicro chassis. See the figure below for the descriptions of the front control panel buttons and LED indicators. Refer to the following section for descriptions and pin definitions.
  • Page 44: Front Control Panel Pin Definitions

    X10SRL-F User’s Manual Front Control Panel Pin Definitions NMI Button NMI Button Pin Definitions (JF1) The non-maskable interrupt button Pin# Definition header is located on pins 19 and 20 Control of JF1. Refer to the table on the right Ground for pin definitions.
  • Page 45: Hdd Led

    NIC2 LED P3V3_STB P3V3_STB NIC1 LED HDD LED UID SW USB4/5 P3V3 Power LED USB6/7 USB8/9 JBT1 JIPMB1 IPMI X10SRL-F Ground Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 JSD2 BIOS LICENSE JWD1 MAC CODE...
  • Page 46: Overheat (Oh)/Fan Fail/Pwr Fail/Uid Led

    X10SRL-F User’s Manual Overheat (OH)/Fan Fail/PWR Fail/ OH/Fan Fail/ PWR Fail/Blue_UID UID LED LED Pin Definitions (JF1) Pin# Definition Connect an LED cable to pins 7 and P5V_STB 8 of Front Control Panel to use the Red_LED-Cathode/OH/Fan Fail/ Overheat, Fan Fail, and Power Fail Power Fail connections.
  • Page 47: Reset Button

    NIC2 LED P3V3_STB P3V3_STB NIC1 LED HDD LED UID SW P3V3 Power LED USB4/5 USB6/7 USB8/9 JBT1 Ground JIPMB1 X10SRL-F IPMI Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 BIOS LICENSE JSD2 JWD1 MAC CODE...
  • Page 48: Connecting Cables

    X10SRL-F User’s Manual Connecting Cables This section provides brief descriptions and pin-out definitions for onboard headers and connectors. Be sure to use the correct cable for each header or connector. For information on Backpanel USB and Front Panel USB ports, refer to page 2-17.
  • Page 49: Fan Headers (Fan 1-Fan 5 & Fan A )

    Chapter 2: Installation Fan Headers (Fan 1-Fan 5 & Fan A ) Fan Header Pin Definitions The X10SRL-F has six fan headers (Fan 1-Fan Pin# Definition 5 & Fan A). These fans are 4-pin fan headers. Ground (Black) Although pins 1-3 of the onboard fan headers 2.5A/+12V...
  • Page 50: Internal Speaker/Buzzer

    X10SRL-F User’s Manual Internal Speaker/Buzzer Internal Buzzer Pin Definition The Internal Speaker/Buzzer (SP1) is Pin# Definitions used to provide audible indications for Pin 1 Pos. (+) Beep In various beep codes. See the table on Pin 2 Neg. (-) Alarm the right for pin definitions.
  • Page 51: Dom Pwr Connector

    USB0/1 LAN2 LAN1 IPMI_LAN LEDM1 JPL2 CTRL JVR1 JPL1 CTRL USB4/5 USB6/7 USB8/9 JBT1 JIPMB1 IPMI X10SRL-F Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 JSD2 BIOS LICENSE JWD1 MAC CODE S-SATA3 JSTBY1 S-SATA2 5V STBY...
  • Page 52: T-Sgpio 1/2/3 Headers

    X10SRL-F User’s Manual T-SGPIO 1/2/3 Headers T-SGPIO/6-SGPIO Pin Definitions Two Serial-Link General Purpose Input/ Pin# Definition Pin# Definition Output headers (T-SGPIO 1/2/3) are located on the motherboard. T-SGPIO Data Ground 1/2/3 support onboard SATA interface. Ground Load See the table on the right for pin defini- Clock tions.
  • Page 53: Tpm Header/Port 80 Header

    LAN2 LAN1 IPMI_LAN JPL2 LEDM1 B. VGA Port CTRL JVR1 JPL1 CTRL USB4/5 USB6/7 USB8/9 JBT1 JIPMB1 X10SRL-F IPMI Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 JSD2 BIOS LICENSE JWD1 MAC CODE S-SATA3 JSTBY1...
  • Page 54: Jumper Settings

    X10SRL-F User’s Manual Jumper Settings Explanation of Jumpers To modify the operation of the mother- board, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit board.
  • Page 55: Cmos Clear

    FAN5 IPMI_LAN LAN2 LAN1 JPL2 LEDM1 CTRL JVR1 JPL1 CTRL USB4/5 USB6/7 USB8/9 JBT1 JIPMB1 IPMI X10SRL-F Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 BIOS LICENSE JSD2 JWD1 MAC CODE S-SATA3 JSTBY1 S-SATA2 5V STBY...
  • Page 56: Manufacture Mode Select

    X10SRL-F User’s Manual Manufacture Mode Select ME Mode Select Jumper Settings Close this jumper (JPME2) to bypass Pin# Definition SPI flash security and force the system Normal (Default) to use the Manufacture Mode which will Manufacture Mode allow the user to flash the system firm- ware from a host server to modify system settings.
  • Page 57: Watch Dog Enable/Disable

    FAN5 LAN2 LAN1 IPMI_LAN LEDM1 JPL2 CTRL JVR1 JPL1 CTRL USB4/5 USB6/7 USB8/9 JBT1 JIPMB1 IPMI X10SRL-F Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 BIOS LICENSE JSD2 JWD1 MAC CODE S-SATA3 JSTBY1 S-SATA2 5V STBY...
  • Page 58: Bmc Enable/Disable (Jpb1)

    X10SRL-F User’s Manual BMC Enable/Disable (JPB1) BMC IPMI Enable/Disable Jumper Settings JPB1 is used to enable or disable Pin # Definition the BMC (Baseboard Management Enabled (Default) Control) chip and the onboard IPMI Disabled connection. This jumper is used to- gether with the IPMI settings in the BIOS.
  • Page 59: Onboard Indicators

    FAN5 IPMI_LAN LAN2 LAN1 JPL2 LEDM1 CTRL JVR1 JPL1 CTRL USB4/5 USB6/7 USB8/9 JBT1 JIPMB1 IPMI X10SRL-F Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 BIOS LICENSE JSD2 JWD1 MAC CODE S-SATA3 JSTBY1 S-SATA2 5V STBY...
  • Page 60: Onboard Power Led

    BMC Heartbeat LED BMC Heartbeat LED Status A BMC Heartbeat LED is located at Color/State Definition LEDM1 on the X10SRL-F. See the table Green: BMC: Normal Blinking on the right for more information. A. BMC LED B. Onboard Power LED...
  • Page 61: 2-10 Sata Connections

    USB0/1 FAN5 IPMI_LAN LAN2 LAN1 JPL2 LEDM1 CTRL JVR1 JPL1 CTRL USB4/5 USB6/7 USB8/9 JBT1 JIPMB1 X10SRL-F IPMI Rev: 1.01 DESIGNED IN USA BAR CODE Intel PCH IPMI CODE JPI2C1 I-SATA5 JSD2 BIOS LICENSE JWD1 MAC CODE S-SATA3 JSTBY1 S-SATA2...
  • Page 62 X10SRL-F User’s Manual Notes 2-40...
  • Page 63: Chapter 3 Troubleshooting

    Chapter 3: Troubleshooting Chapter 3 Troubleshooting Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘Technical Support Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter. Always disconnect the AC power cord before adding, changing or installing any hardware components.
  • Page 64: No Video

    X10SRL-F User’s Manual No Video 1. If the power is on, but you have no video--in this case, you will need to re- move all the add-on cards and cables first. 2. Use the speaker to determine if any beep codes exist. (Refer to Appendix A for details on beep codes.)
  • Page 65: Technical Support Procedures

    Before contacting Technical Support, please make sure that you have followed all the steps listed below. Also, Note that as a motherboard manufacturer, Supermicro does not sell directly to end users, so it is best to first check with your distributor or reseller for troubleshooting services.
  • Page 66: Frequently Asked Questions

    Frequently Asked Questions Question: What type of memory does my motherboard support? Answer: The X10SRL-F supports up to 256GB of RDIMM and 512Gb of LRDIMM DDR4 2400 MHz (max.) in eight memory slots. See Section 2-5 for details on installing memory.
  • Page 67: Battery Removal And Installation

    Chapter 3: Troubleshooting Battery Removal and Installation Battery Removal To remove the onboard battery, follow the steps below: 1. Power off your system and unplug your power cable. 2. Locate the onboard battery as shown below. 3. Using a tool such as a pen or a small screwdriver, push the battery lock out- wards to unlock it.
  • Page 68: Returning Merchandise For Service

    X10SRL-F User’s Manual Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered. You can obtain service by calling your vendor for a Returned Merchandise Authorization (RMA) number. For faster service, you may also obtain RMA authorizations online (http://www.supermicro.
  • Page 69: Chapter 4 Bios

    BIOS Introduction This chapter describes the AMI BIOS setup utility for the X10SRL-F. The ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS setup utility screens.
  • Page 70: Main Setup

    Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential dam- ages arising from a BIOS update. If you have to update the BIOS, do not shut down or reset the system while the BIOS is updating.
  • Page 71 Day MM/DD/YYYY format. The time is entered in HH:MM:SS format. Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00. Supermicro X10SRL-F BIOS Version: This item displays the version of the BIOS ROM used in the system.
  • Page 72: Advanced Setup Configurations

    X10SRL-F User’s Manual Advanced Setup Configurations Use the arrow keys to select Advanced setup and press <Enter> to access the submenu items: Warning: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency or an incorrect BIOS timing setting may cause the system to malfunction.
  • Page 73 Chapter 4: AMI BIOS Wait For 'F1' If Error Select Enabled to force the system to wait until the 'F1' key is pressed if an error occurs. The options are Disabled and Enabled. INT19 (Interrupt 19) Trap Response Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Immediate, the ROM BIOS of the host adaptors will "capture"...
  • Page 74 X10SRL-F User’s Manual CPU Configuration  Warning! Setting the wrong values in the following sections may cause the system to malfunction. CPU Configuration The following CPU information will be displayed: • Processor Socket • Processor ID • Processor Frequency •...
  • Page 75 Chapter 4: AMI BIOS Execute Disable Bit (Available if supported by the OS & the CPU) Set to Enabled for Execute Disable Bit support which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot, thus preventing a worm or a virus from flooding illegal codes to over- whelm the processor or damaging the system during a virus attack.
  • Page 76 X10SRL-F User’s Manual X2APIC (Extended Advanced Programmable Interrupt Controller) Based on the Intel Hyper-Threading technology, each logical processor (thread) is assigned 256 APIC IDs (APIDs) in 8-bit bandwidth. When this item is set to En- able, the APIC ID will be expanded from 8 bits to 16 bits to provide 512 APIDs to each thread to enhance CPU performance.
  • Page 77 Chapter 4: AMI BIOS P-state Coordination Use this item to configure the processor's P-State coordination settings. During a P-State, the voltage and frequency of the processor will be reduced when it is in operation. This makes the processor more energy efficient, resulting in further energy gains.
  • Page 78 X10SRL-F User’s Manual Chipset Configuration North Bridge This feature allows the user to configure the settings for the Intel North Bridge. IIO Configuration EV DFX (Device Function On-Hide) Feature When this feature is set to Enable, the EV_DFX Lock Bits that are located on a processor will always remain clear during electric tuning.
  • Page 79 Chapter 4: AMI BIOS No Snoop Select Enable to support no-snoop mode for each CB device. The options are Disable and Enable. Relaxed Ordering Select Enable to enable Relaxed Ordering support which will allow certain trans- actions to violate the strict-ordering rules of PCI and to be completed prior to other transactions that have already been enqueued.
  • Page 80 X10SRL-F User’s Manual COD Enable (Available when the OS and the CPU support this feature) Select Enabled for Cluster-On-Die support to enhance system performance in cloud computing. The options are Enabled and Disabled. Early Snoop (Available when the OS and the CPU support this feature) Select Enabled for Early Snoop support to enhance system performance.
  • Page 81 Chapter 4: AMI BIOS A7 Mode Select Enabled to support A7 (Addressing) Mode to improve memory perfor- mance. The options are Enable and Disable. DIMM Information This item displays the status of a DIMM module specified. • DIMMA1 • DIMMA2 •...
  • Page 82 X10SRL-F User’s Manual Patrol Scrub Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected in a memory module and send the correction to the requestor (the original source). When this item is set to Enable, the IO hub will read and write back one cache line every 16K cycles if there is no delay caused by internal processing.
  • Page 83 Chapter 4: AMI BIOS South Bridge  The following South Bridge information will display:\ • USB Configuration • USB Module Version • USB Devices Legacy USB Support Select Enabled to support onboard legacy USB devices. Select Auto to disable legacy support if there are no legacy USB devices present. Select Disable to have all USB devices available for EFI applications only.
  • Page 84 X10SRL-F User’s Manual XHCI Pre-Boot Driver Select Enabled to enable XHCI (Extensible Host Controller Interface) support on a pre-boot drive specified by the user. The options are Enabled and Disabled. SATA Configuration  When this submenu is selected, the AMI BIOS automatically detects the presence...
  • Page 85 Chapter 4: AMI BIOS Port 0 ~ Port 5 Spin Up Device On an edge detect from 0 to 1, set this item to allow the PCH to initialize the device. The options are Enabled and Disabled. Port 0 ~ Port 5 SATA Device Type Use this item to specify if the SATA port specified by the user should be con- nected to a Solid State drive or a Hard Disk Drive.
  • Page 86 X10SRL-F User’s Manual Port 0~ Port 5 Select Enabled to enable a SATA port specified by the user. The options are Disabled and Enabled. Port 0 ~ Port 5 Spin Up Device On an edge detect from 0 to 1, set this item to allow the PCH to start a COMRE- SET initialization to the device.
  • Page 87 Chapter 4: AMI BIOS sSATA Port 0~ Port 3 Select Enabled to enable an sSATA port specified by the user. The options are Disabled and Enabled. sSATA Port 0 ~ Port 3 Spin Up Device On an edge detect from 0 to 1, set this item to allow the PCH to start a COMRE- SET initialization to the device.
  • Page 88 X10SRL-F User’s Manual • Software Preserve Support sSATA Port 0~ Port 3 Select Enabled to enable an sSATA port specified by the user. The options are Disabled and Enabled. sSATA Port 0 ~ Port 3 Spin Up Device On an edge detect from 0 to 1, set this item to allow the PCH to start a COMRE- SET initialization to the device.
  • Page 89 Chapter 4: AMI BIOS PCI PERR/SERR Support Select Enabled to allow a PCI device to generate a PERR/SERR number for a PCI Bus Signal Error Event. The options are Enabled and Disabled. Above 4G Decoding (Available if the system supports 64-bit PCI decoding) Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address.
  • Page 90 X10SRL-F User’s Manual Select Enabled to enable Option ROM support to boot the computer using a de- vice installed on the slot specified by the user. The options are Disabled, Legacy and EFI. Onboard LAN Option ROM Type Use this item to select the Onboard LAN Option ROM type. The options are Legacy and EFI.
  • Page 91 Chapter 4: AMI BIOS The options for Serial Port 1 are Auto, (IO=3F8h; IRQ=4), (IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), (IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12); (IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12), and (IO=2E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12). The options for Serial Port 2 are Auto, (IO=3F8h;...
  • Page 92 X10SRL-F User’s Manual Parity A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd.
  • Page 93 Chapter 4: AMI BIOS Redirection After BIOS Post Use this feature to enable or disable legacy Console Redirection after BIOS POST. When set to Bootloader, legacy Console Redirection is disabled before booting the OS. When set to Always Enable, legacy Console Redirection remains enabled when booting the OS.
  • Page 94 X10SRL-F User’s Manual Parity A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd.
  • Page 95 Chapter 4: AMI BIOS Redirection After BIOS Post Use this feature to enable or disable legacy Console Redirection after BIOS POST. When set to Bootloader, legacy Console Redirection is disabled before booting the OS. When set to Always Enable, legacy Console Redirection remains enabled when booting the OS.
  • Page 96 X10SRL-F User’s Manual Flow Control Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty.
  • Page 97: Event Logs

    Chapter 4: AMI BIOS Event Logs Use this feature to configure Event Log settings. Change SMBIOS Event Log Settings  This feature allows the user to configure SMBIOS Event settings. Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during system boot.
  • Page 98 X10SRL-F User’s Manual Erasing Settings Erase Event Log Select Enabled to erase all error events in the SMBIOS (System Management BIOS) log before an event logging is initialized at bootup. The options are No and Yes. When Log is Full Select Erase Immediately to immediately erase all errors in the SMBIOS event log when the event log is full.
  • Page 99: Ipmi

    Chapter 4: AMI BIOS IPMI Use this feature to configure Intelligent Platform Management Interface (IPMI) settings. IPMI Firmware Revision This item indicates the IPMI firmware revision used in your system. IPMI Status This item indicates the status of the IPMI firmware installed in your system. System Event Log ...
  • Page 100 X10SRL-F User’s Manual When SEL is Full This feature allows the user to determine what the BIOS should do when the sys- tem event log is full. Select Erase Immediately to erase all events in the log when the system event log is full. The options are Do Nothing and Erase Immediately.
  • Page 101 Chapter 4: AMI BIOS Gateway IP Address This item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i.e., 192.168.10.253). 4-33...
  • Page 102 X10SRL-F User’s Manual Security This menu allows the user to configure the following security settings for the system. Password Check Select Setup for the system to check for a password at Setup. Select Always for the system to check for a password at bootup or upon entering the BIOS Setup utility.
  • Page 103: Boot

    Chapter 4: AMI BIOS Boot Use this feature to configure Boot Settings: Setup Prompt Timeout Use this item to indicate the length of time (the number of seconds) for the BIOS to wait before rebooting the system when the setup activation key is pressed. Enter the value of 65535 (0xFFFF) for the BIOS to wait indefinitely.
  • Page 104 X10SRL-F User’s Manual • Dual Boot Order #7 • Dual Boot Order #8 • Dual Boot Order #9 • Dual Boot Order #10 • Dual Boot Order #11 • Dual Boot Order #12 • Dual Boot Order #13 • Dual Boot Order #14 •...
  • Page 105: Save & Exit

    Chapter 4: AMI BIOS Save & Exit Select the Save & Exit tab from the BIOS setup screen to configure the settings below. Discard Changes and Exit Select this option to quit the BIOS setup without making any permanent changes to the system configuration, and reboot the computer.
  • Page 106 X10SRL-F User’s Manual Restore Optimized Defaults To set this feature, select Restore Optimized Defaults from the Exit menu and press <Enter>. These are factory settings designed for maximum system performance but not for maximum stability. Save as User Defaults To set this feature, select Save as User Defaults from the Exit menu and press <En- ter>.
  • Page 107: Appendix A Bios Error Beep Codes

    Appendix A: POST Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue with bootup.
  • Page 108 X10SRL-F User’s Manual Notes...
  • Page 109: Appendix B Software Installation Instructions

    Appendix B Software Installation Instructions B-1 Installing Software Programs The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. After accessing the ftp site, go into the CDR_Images directory and locate the ISO file for your motherboard.
  • Page 110: B-2 Installing Superdoctor5

    X10SRL-F User’s Manual B-2 Installing SuperDoctor5 The Supermicro SuperDoctor® 5 is a hardware monitoring program that functions in a command-line or web-based interface in Windows and Linux operating systems. The program monitors system health information such as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 111: Appendix C Uefi Bios Recovery Instructions

    Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you need to update the BIOS, do not shut down or reset the system while the BIOS is updating to avoid possible boot failure.
  • Page 112 Root "\" Directory of a USB device or a writeable CD/DVD. Note: If you cannot locate the "Super.ROM" file in your driver disk, visit our website at www.supermicro.com to download the BIOS image into a USB flash device and rename it "Super.ROM" for BIOS recovery use.
  • Page 113 Appendix C: UEFI BIOS Recovery 4. After locating the new BIOS binary image, the system will enter the BIOS Recovery menu as shown below. Note: At this point, you may decide if you want to start with BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below. 5.
  • Page 114 X10SRL-F User’s Manual 6. After the process of BIOS recovery is completed, press any key to reboot the system. 7. Using a different system, extract the BIOS package into a bootable USB flash drive. 8. When a DOS prompt appears, enter FLASH.BAT BIOSname.### at the prompt.
  • Page 115: Appendix D Dual Boot Block On Grantley Platforms

    Dual Boot Block on Grantley Platforms Overview On X10 Grantley platforms, Supermicro introduces the Dual Boot Block feature that revives the system from an inert state if the primary boot block in the ROM chip is damaged. A boot block carries critical codes to boot the system with minimum hardware requirements for the BIOS recovery flash.
  • Page 116: D-1 Ipmi Gui Browser

    X10SRL-F User’s Manual D-1 IPMI GUI Browser To perform perform the Dual Boot Block through the IPMI GUI browser, follow the instructions below: 1. After the IPMI GUI browser log-in, click on the Miscellaneous tab, then BIOS Resilience, then the Resile button.
  • Page 117 Appendix D: Dual Boot Block 3. Click on the Remote Control tab, then Console Redirection, then the Launch Console button to open the Java iKVM Viewer. 4. In the Java iKVM Browser, click on the Virtual Media tab, then Virtual Stor- age to open the Virtual Media Loader.
  • Page 118 X10SRL-F User’s Manual 5. In the Virtual Media loader, click on the Device1 tab, then Logical Drive Type drop-down menu, then select the USB flash drive with Super.ROM. Click Plug In, then OK. 6. Click on the Remote Control tab, then Power Control, then check the Power On Server button.
  • Page 119 Appendix D: Dual Boot Block 7. After the system powers on, the secondary boot block starts to initialize the essential hardware components and locates Super.ROM in the USB flash drive, which was mounted earlier. If Super.ROM is found, the on-duty boot block boots to it and finishes the rest of the POST processes.
  • Page 120 X10SRL-F User’s Manual 9. A message box will appear to indicate the BIOS recovery flash process is complete. Press ENTER to finish. The system will do a power cycle to deacti- vate the dual boot block feature and produce a normal BIOS POST.
  • Page 121: D-2 Ipmi Command Sets

    Appendix D: Dual Boot Block D-2 IPMI Command Sets To perform perform the Dual Boot Block through the IPMI Command Sets, follow the instructions below: 1. After the IPMI GUI browser log-in, click on the Remote Control tab, then Console Redirection, then the Launch Console button to open Java iKVM Viewer.
  • Page 122 X10SRL-F User’s Manual 3. Enable BIOS Resilience mode in remote IPMI and confirm. • To enable, type the following command in the command prompt: ipmi raw 30 70 C2 D5 00 00 • To confirm, type the following command in the command prompt: impi raw 30 70 C3 D5 4.
  • Page 123: User Approach

    Appendix D: Dual Boot Block 5. Power on the remote system for BIOS recovery flash. • To power on, type: ipmi power up After the system powers on, the secondary boot block initializes the essential hardware components and locates Super.ROM in the USB flash drive, which are the same as Steps 7-9 in Section D-1.
  • Page 124 X10SRL-F User’s Manual Notes D-10...