9. Appendix

Appendix C: Battery Using Guide

Battery electric quantity indicating symbols
、 、 and
include:
power indication
Fig.9-1 Battery
Charging the oscilloscope
Connect the power cord to a power source. Turn on the Power Switch Button ― ○ on
the left side (make sure the "―" side is pressed down). Yellow light of the indicator on
the front panel means the battery is being charged. Once the battery is full, the indicator
will become green. The lithium battery maybe not be charged when delivery. Please
charge the battery for 12 hours to make sure enough power to supply to oscilloscope. The
battery can supply power for 4 hours after being charged completely.
There will have battery power indication show on the top of panel when oscilloscope
power supplied by the battery ( if no indication has appeared, see "Display" on P55 ).
, ,
and
imply for different power consumption and when
shows it means the
power can only supply for 5 minutes maximum.
Note:
To avoid superheat of battery during charging, the environment temperature is not allowed
to exceed the permissible value given in technical specification.
Replacing the Lithium Battery Unit
It is usually not required to replace the battery unit. But when it is required to replace it,
only qualified personnel can carry out this operation, and only use the same specification
lithium battery.