Section 7 Sailplane and system description
7.3 Cockpit, cockpit controls and placards
Subsection amended
Controls and control lights for
the electrically operated
landing gear in front and rear
instrument panel (upper left
hand side):
40)
Toggle switch for extension and retraction of the electrically operated
main landing gear
up
down
41)
Press button for retraction of the electrically operated main landing gear
For retraction switch and hold the toggle switch up and press the press
button 2 times within 2 seconds.
42) – 44)
control lights (LED's) for the electrically operated main landing
gear:
Condition
Normal operation
LG retracted and locked
LG extended and locked
LG retracting
LG extending
LG stopped in intermediate
position
Emergency operation
LG extends
LG extended and locked
System resetting
Failure messages
Time overflow: Signal appears if
within 22 seconds after start of
the travelling no limit switch
activates
One limit switch defective
Note: To save electrical power during flight the upper green LED will stop
shining after approx. 5 minutes if the landing gear is retracted and locked.
Issued: November 2008
Flight manual DG-1000T
retracted and locked
extended and locked over centre
control light indication
42) upper green shines
44) lower green shines
43) red shines, 42) upper green blinking
43) red shines, 44) lower green blinking
43) red shines
43) red shines
44) lower green shines, 43) red shines
44) lower green shines, 43) red shines
43) red blinking + upper or lower green
blinking according to travel direction
all LED's blinking
TN 1000/14