I -
TV Receiver, Setup, and AUX CTRL Menu Maps and Softkey Descriptions
The System Beats softkey is used to specify the channel you wish to
use for testing beats. The default channel is 4. The default measurement
frequency for CTB is 6 MHz above the visual carrier; the default measurement
frequency for CSO is 4.75 MHz above the visual carrier. These values can be
changed using CT3 FREQ OFFSET and CSO FREQ OFFSET .
These settings are stored in nonvolatile analyzer memory. This means that
the analyzer retains the selections, even when power is turned off, until a
new selection is made.
Press CABLE TV ANALYZER, Setup to access System Beats .
See Also
Descriptions for above mentioned softkeys in this chapter.
"Step 1. ConEgure the test system" in Chapter 3.
7-18