1. Tie rod
5. Rotate both tie rods to move the front of the tire
inward or outward.
6. Tighten the tie rod jam nuts when the adjustment is
correct.
7. Ensure that there is full travel of the steering wheel in
both directions.
Checking the Transaxle-Fluid
Level
Service Interval: Every 100 hours
Fluid Type: SAE 10W-30 (API service SJ or higher)
1. Move the machine to a level surface, shut off the
machine, engage the parking brake, and remove the key.
2. Remove the fill plug on the transaxle
1. Drain plug
3. If the fluid level is low, remove the fill plug and add the
specified fluid until it runs out of the hole
4. Replace the fill plug and torque it to 20 to 27 N∙m (15
to 20 ft-lb).
Figure 45
2. Jam nut
(Figure
Figure 46
2. Fill plug
(Figure

Changing the Transaxle Fluid

Service Interval: Every 800 hours/Yearly (whichever comes
Fluid Type: SAE 10W-30 (API service SJ or higher)
Fluid Capacity: 1.4 L (1.5 US qt)
1. Align a drain pan under the drain plug
2. Remove the fill plug and the seal
Note: Retain the fill plug and seal for installation in
step 6.
3. Remove the drain plug and the seal, and allow the fluid
to drain completely
Note: Retain the drain plug and seal for installation
in step 4.
4. Install the drain plug and seal, and torque it to 20 to 27
N∙m (15 to 20 ft-lb).
5. Fill the transaxle with the specified fluid until it runs
out of the fill hole.
6. Install the fill plug and seal, and torque it to 20 to 27
N∙m (15 to 20 ft-lb).