82 | Configuring the Terminal
1. Select the Display Locally setting for each alarm input.
Display Locally
No
Yes
2. Select the Severity setting for each alarm input.
This option is only relevant when the 'Display Locally' option is set to 'Yes'.
Severity
Minor
Major
3. Enter a Description for each alarm input. The default is 'External Input 1' / 'External Input 2'.
4. Select the Alarm On When setting for each alarm input.
Alarm On When
External Source On
External Source Off
5. When you have made your changes, click Apply to apply changes or Reset to restore the previous
configuration.
External Alarm Input Function
The external alarm input does not generate an alarm on the
local terminal, does not appear in the 'Alarm Table' or 'Alarm
History', and shows as grayed out on the 'Alarm Summary'.
The external alarm input generates an alarm on the local
terminal, displays in the 'Alarm Table' and 'Alarm History' and
the 'Alarm Summary'.
External Alarm Input Severity
The external alarm input generates a minor alarm on the local
terminal.
The external alarm input generates a major alarm on the local
terminal.
External Alarm Input State
The alarm is on (alarm active) when a source of voltage is
applied to the external alarm input and current is flowing.
The alarm is on (alarm active) when no source of voltage is
applied to the external alarm input and hence no current is
flowing.
Aprisa XE User Manual
Default
Default