12 VDC Cable
The 12 VDC power supply is supplied with a 3 metre red/black cable of two pairs of 2.3 mm
0.2 mm
) making a total of 4.6 mm
2
current consumption of the 12 VDC supply (max 18 Amps per terminal).
This 3 metre cable is engineered to power a fully loaded terminal from a 12 VDC supply. A longer cable
should not be used as the additional voltage drop could cause the power supply to fail.
If longer cable runs are required between the 12 VDC power supply and the terminal, it is suggested that
high current distribution bus bars are used to feed the rack and the supplied power cable used between
the bus bars and the terminals.
1. Fit both pairs of lugs into the terminal screw
clamps.
per connection. This increase in wire size is to carry the increased
2
Terminal
Power input
+V
Positive DC input
-V
Negative DC input
2. Twist the other ends together when fitting
to the source.
Aprisa XE User Manual
Mounting and Installing the Terminal | 39
(72 strands of
2
Cable colour
Red
Black