Environmental Monitoring And Reporting Functions; Cisco Asr1001-X Router Alarm Monitoring - Cisco ASR 1001-X Hardware Installation Manual

Table of Contents

Advertisement

Cisco ASR 1001-X Router Power Up and Initial Configuration
Apr 21 03:42:45.619 EDT: %SYS-5-RELOAD: Reload requested by console. Reload Reason: Reload Command.Apr
21 03:42:59.920 R0/0: %PMAN-5-EXITACTION: Process manager is exiting: process exit with reload
chassis code
Step 4
After confirming the reload command, wait until the system bootstrap message is displayed before powering off the
system:
Example:
System Bootstrap, Version 15.4(2r)S, RELEASE SOFTWARE (fc1)
Copyright (c) 1994-2014
Current image running: Boot ROM0
Last reset cause: LocalSoft
ASR1001-X platform with 16777216 Kbytes of main memory
rommon 1 >
Step 5
Place the Standby switch in the Standby position.
The fans in the power supply modules will continue to run even if the Standby switch is in the Standby position.
Note
Note
After powering off the router, wait for a minimum of 30 seconds before powering it on again.

Environmental Monitoring and Reporting Functions

Environmental monitoring and reporting functions allow you to maintain normal system operation by identifying
and resolving adverse conditions prior to loss of operation.
To prevent overheating of the chassis, ensure that your system is drawing cool inlet air. Over temperature
Caution
conditions may occur if the system is drawing in the exhaust air of other equipment. Ensure adequate
clearance around the sides of the chassis so that cooling air can flow through the chassis interior unimpeded
and exhaust air exits the chassis and is not drawn into the inlet vent of another device.

Cisco ASR1001-X Router Alarm Monitoring

The Cisco ASR 1001-X Router displays the CRIT, MAJ, and MIN alarm indicator LEDs. The three system
alarm LEDs on the Cisco ASR 1001-X Router provide visual alarm notification in the router. These LEDs
indicate router status at all times, but you must directly observe these LEDs to become aware of a router alarm
condition. Additionally, you can use the show facility-alarm status command to view the alarms.
Router# show facility-alarm status
System Totals
Source
------
Power Supply Module 1
xcvr container 0/0/0
Down [1]
xcvr container 0/0/1
xcvr container 0/0/2
Down [1]
xcvr container 0/0/3
Down [1]
xcvr container 0/0/4
xcvr container 0/0/5
by cisco Systems, Inc.
Critical: 4
Major: 0
Minor: 0
Time
------
Mar 12 2014 09:05:21
Mar 12 2014 09:05:42
Mar 12 2014 09:05:42
Mar 12 2014 09:05:42
Mar 12 2014 09:05:42
Mar 12 2014 09:05:42
Mar 12 2014 09:05:42

Environmental Monitoring and Reporting Functions

Severity
Description [Index]
--------
-------------------
CRITICAL
Power Supply Failure [0]
CRITICAL
Transceiver Missing - Link
INFO
Transceiver Missing [0]
CRITICAL
Transceiver Missing - Link
CRITICAL
Transceiver Missing - Link
INFO
Transceiver Missing [0]
INFO
Transceiver Missing [0]
Cisco ASR 1001-X Router Hardware Installation Guide