FX Series Programmable Controlers
5.5.7
ANS (FNC 46)
Mnemonic
ANS
FNC 46
(Timed
annunciator
set)
16 BIT OPERATION
If the instruction is switched OFF during or after completion of the timing cycle the timer is
automatically reset. However, the current status of the annunciator coil remains unchanged.
Note: This is only one method of driving annunciator coils, others such as direct setting can
also be used.
Function
This instruction
T
starts a timer.
Note:
Once timed out
available
the selected
range
annunciator flag is
T0 to T199
set ON
32 BIT OPERATION
Operands
S
D
S
Note:
annunciator
range S900 to
S999
PULSE-P
Operation:
This instruction, when energized, starts a timer (S)
for n,100 msec. When the timer completes its cycle
the assigned annunciator (D) is set ON.
Applied Instructions 5
FX
FX
FX
1N
2N
1S
Program steps
n
K
ANS:
7 steps
Note:
n range 1 to
32,767 - in
units of
100msec
5-61
FX