Or, Or Inverse - Mitsubishi FX1S Series Programming Manual

Melsec-f
Hide thumbs Also See for FX1S Series:
Table of Contents

Advertisement

FX Series Programmable Controllers
2.7

Or, Or Inverse

Mnemonic
OR
(OR)
ORI
(OR Inverse)
Program example:
X4
X6
M102
Y5
M103
M110
Basic points to remember:
- Use the OR and ORI instructions for parallel connection of contacts. To connect a block
that contains more than one contact connected in series to another circuit block in
parallel, use an ORB instruction.
- Connect one side of the OR/ORI instruction to the left hand bus bar.
Peripheral limitations:
• The PLC has no limit to the number of contacts connected in series or in parallel.
However, some programming panels, screens and printers will not be able to display
or print the program if it exceeds the limit of the hardware. It is preferable for each
line or rung of ladder program to contain up to a maximum of 10 contacts and 1 coil.
Also keep number of follow-on outputs to a maximum of 24.
Function
Parallel
connection of NO
(normally open)
contacts
Parallel
connection of NC
(normally closed)
contacts
OR
ORI
X7
X10
FX
Format
X, Y, M, S, T, C
X, Y, M, S, T, C
Y5
M103
Basic Program Instructions 2
FX
FX
1S
1N
2N
Devices
Program steps
0
LD
X
OR
1
X
2
ORI
M
Y
3
OUT
4
LDI
Y
X
5
AND
6
OR
M
7
ANI
X
OR
M
8
9
OUT
M
2-7
FX
2NC
1
1
4
6
102
5
5
7
103
10
110
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx1n seriesFx2nc seriesFx2n series

Table of Contents