Huawei AR1200 Series Enterprise Routers
Configuration Guide - MPLS
Procedure
l
l
----End

2.7.4 (Optional) Setting the Hold-max-cost Timer Value

You can set the value of a hold-max-cost timer, that is, an interval for advertising the maximum
cost through LSAs generated locally.
Context
Perform the following steps on the interface:
Procedure
l
Issue 01 (2011-12-30)
When OSPF runs as an IGP, perform the following steps on the interfaces of both ends of
the link between the crossing node of active and standby links and the LDP neighboring
node on the active link:
1.
Run:
system-view
The system view is displayed.
2.
Run:
interface interface-type interface-number
The interface view is displayed.
3.
Run:
ospf timer ldp-sync hold-down value
The interval during which OSPF waits for an LDP session to be established is set.
By default, the hold-down timer is 10 seconds.
When IS-IS runs as an IGP, perform the following steps on the interfaces of both ends of
the link between the crossing node of active and standby links and the LDP neighboring
node on the active link:
1.
Run:
system-view
The system view is displayed.
2.
Run:
interface interface-type interface-number
The interface view is displayed.
3.
Run:
isis timer ldp-sync hold-down value
The interval during which IS-IS waits for an LDP session to be established is set.
By default, the hold-down timer value is 10 seconds.
When OSPF runs as an IGP, perform the following steps on the interfaces of both ends of
the link between the crossing node of active and standby links and the LDP neighboring
node on the active link:
1.
Run: