Specification; Troubleshooting - XYZ Printing Nobel Superfine User Manual

Hide thumbs Also See for Nobel Superfine:
Table of Contents

Advertisement

Specification

Nobel Superfine Printer
Print Technology
DLP(Digital Light Processing)
UV Light Source
UV LED λ 405nm
Maximum Printing Area(W*D*H)
64 *40 *120mm
X/Y Axis Resolution
50µm
Z Axis Resolution
25µm / 50µm / 100µm
File Format
.stl / XYZ format .3ws/.3wn
Connectivity
USB Cable & USB drive & WIFI

Troubleshooting

When an error occurs, please refer to the service code on the printer and/or in the software, and check the suggestion below for troubleshooting. If any error persists,
please contact customer service center for support.
● Error Code 1001: Z axis motor upward movement abnormalities or Z axis top sensor malfunctioned
Suggestion:
Select "INFO">"SENSOR STATUS" on the printer, touch Z axis top sensor, and see if the status of "Z-T" switches from 0 to 1. If the value doesn't switch accordingly, then
the sensor is malfunctioning. Then select "UTILITIES">"MOVE PLATFORM">"TO TOP" to raise the . If the platform doesn't rise accordingly, then the motor is malfunction-
ing. Contact the service center after you have checked the status of the printer.
● Error Code 1002: Z axis motor downward movement abnormalities or Z axis bottom sensor malfunctioned
Suggestion:
Select "INFO">"SENSOR STATUS" on the printer, touch Z axis bottom sensor, and see if the status of "Z-B" switches from 0 to 1. If the value doesn't switch accordingly,
then the sensor is malfunctioning. Then select "UTILITIES">"MOVE PLATFORM">"TO BOTTOM" to descend the platform. If the platform doesn't descend accordingly,
then the motor is malfunctioning. Contact the service center after you have checked the status of the printer.
AC Input
100-240V 50/60Hz, 24V/2.5A(60W)
Printer Dimension(W*D*H)
290 * 357 * 426.5 mm
Net Weight
11 Kg
Print Material
Photopolymer Resin
Windows 7, 8, 10
OS Support
Mac OS X 10.9 / 10.10 / 10.11 / 10.12
Please ensure that the recommended operating
Operating Conditions
conditions are adhered to. (Operating temperature
20-30°C (68-86°F)/ humidity 40 ~ 60% RH; If a different
operating temperature is printed on the label on the
resin bottle, please adhere to recommended conditions
on the label.)