ALLOWABLE
PARAMETER
On / Off
Metric Units
Metric_Units
On / Off
OptionBits3 [Bit 5]
0x306C 0x00
10.0 – 3000.0
Speed to RPM
Speed_to_RPM
100 – 30000
0x304C 0x00
0 – 8000 rpm
Capture Speed 1
Capture_Speed_1
0 – 8000
0x3079 0x00
0 – 8000 rpm
Capture Speed 2
Capture_Speed_2
0 – 8000
0x3886 0x00
1 – 1320
Capture Distance 1
Capture_Distance_1
1 – 1320
0x307A 0x00
1 – 1320
Capture Distance 2
Capture_Distance_2
1 – 1320
0x3883 0x00
1 – 1320
Capture Distance 3
Capture_Distance_3
1 – 1320
0x3884 0x00
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual,
2 4 N O V E M B E R 2 0 1 5

VEHICLE MENU

RANGE
When this parameter is programmed On, the distance variables (Vehicle
Odometer, Braking Distance Captured, Distance Since Stop, Distance Fine,
and the Capture Distance variables) will accumulate and display in metric
units (km, meters, or decimeters). When programmed Off, the distance
variables will accumulate and display in English units (miles, feet, or inches).
Distance variables are displayed in the Monitor
This parameter affects the vehicle speed displayed in the Monitor
menu (see page 79), and also modifies the VCL variable Vehicle_Speed;
it does not affect actual vehicle performance. The value entered for Speed
to RPM is a conversion factor that scales motor speed to vehicle speed.
KPH to RPM: (G/d)*5305, where G = gear ratio, d = tire diameter [mm].
MPH to RPM: (G/d)*336.1, where G = gear ratio, d = tire diameter [in].
The controller captures the time it takes the motor to go from 0 rpm to the
programmed Capture Speed. The result is stored as "Time to Speed 1"
in the Monitor
motor accelerates from zero speed.
This parameter allows a second capture speed to be defined, and works
identically to Capture Speed 1. The result is stored as "Time to Speed 2"
in the Monitor
The controller captures the time it takes the vehicle to travel from 0 rpm to
the programmed Capture Distance. The result is stored as "Time to Dist 1"
in the Monitor
vehicle accelerates from zero speed.
Note: For accurate distance measuring, the Speed to RPM parameter
must be set correctly.
With the Metric Units parameter programmed Off, distance is in units
of feet. With Metric Units programmed On, distance is in units of meters.
This parameter allows a second capture distance to be defined, and works
identically to Capture Distance 1. The result is stored as "Time to Dist 2"
in the Monitor
This parameter allows a third capture distance to be defined, and works
identically to Capture Distance 1. The result is stored as "Time to Dist 3"
in the Monitor
3 — PROGRAMMABLE PARAMETERS:
DESCRIPTION
»
Vehicle menu (page 83). This timer starts every time the
»
Vehicle menu (page 83).
»
Vehicle menu (page 83). This timer starts every time the
»
Vehicle menu.
»
Vehicle menu.
30
os
Vehicle Parameters
»
Vehicle menu, page 83.
»
Motor
67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1234e1234se1236e1236se1238e1232se

Table of Contents